Genuine AirTAC welding clamp cylinder, order code JCK50X105K from the JCK50 range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
The JCK50X105K is the AirTAC JCK50 power clamp ordered with no factory clamp arm, so you fit your own clamping lever or hook to the output shaft. The bore is 50 mm, the opening angle is coded at 105 degrees, and the toggle-link crank-slider mechanism holds the clamp closed even when air supply is interrupted. It is double acting with PT1/4 ports and produces 160 Nm of output torque at 0.5 MPa, holding up to 800 Nm once clamped.
The K suffix adds a PNP electrical position sensor, so your PLC sees the clamp state directly instead of relying on timer logic. Running air filtered to 40 um at 0.3-0.8 MPa, the unit clamps and opens in a minimum of 1 s each with air cushioning, and the body mounts on four faces with DIN-standard dimensions. Whichever arm you fit, respect the load-torque limit of 4.5 Nm at a 1 s cycle or 6.7 Nm at 2 s.
| Order code | JCK50X105K |
|---|---|
| Product | Welding Clamp Cylinder |
| Opening angle | 105° |
| Arm position and clamp arm | Horizontal arm · No clamp arm |
| Sensor and thread | PNP electrical sensor (K) · PT thread |
| Bore | 50 mm |
|---|---|
| Port | PT1/4 |
| Output torque (0.5 MPa) | 160 N·m |
| Maximum holding torque | 800 N·m |
| Maximum load torque | 4.5 N·m (1 s cycle) · 6.7 N·m (2 s cycle) |
| Clamping torque 0.3 / 0.5 / 0.8 MPa | 99 / 165 / 264 N·m |
| Weight (135°, 15 mm arm) | 4.0 kg |
| Acting | Double acting |
| Fluid | Air, filtered to 40 µm |
| Operating pressure | 0.3 - 0.8 MPa (43 - 116 psi) |
| Proof pressure | 1.2 MPa (175 psi) |
| Temperature | -20 to +70 °C |
| Opening angle | 15 - 135° in 15° steps |
| Clamp / open time | 1 s / 1 s minimum |
| Position sensing | Electrical or pneumatic sensor |
| Cushion | Air cushion |
Source: AirTAC JCK series datasheet (p.373-374, p.387), ordering code and specifications.
Choose JCK50X105K rather than the KN or KA versions when your I/O cards are PNP. The blank arm field is the difference from JCK50X105AM1 through AM4 codes: those ship with an AirTAC arm in R, C or L hole layouts, while this code leaves the arm to you. If 105 degrees is more swing than the fixture needs, the JCK50X90 code saves opening clearance, and the 120 and 135 degree siblings suit wider part ejection; G instead of blank at the end switches the thread from PT to G.
Because no clamp arm is fitted, fixture builders weld or bolt their own lever geometry to the shaft, while the PNP sensor still reports clamp position back to the control system.
The 105 degree opening clears tool tippers and part cranes, and 800 Nm holding torque keeps the fixture locked through machining loads even on lost air.
With a minimum 1 s clamp and 1 s open time and air cushioning, the clamp fits pick-and-place cycle times on assembly lines running 0.3-0.8 MPa plant air.
Bore 50 mm, opening angle 105 degrees, no factory clamp arm (fit your own), PNP electrical position sensor, PT1/4 ports, output torque 160 Nm at 0.5 MPa, holding torque 800 Nm, clamping torque 99/165/264 Nm at 0.3/0.5/0.8 MPa, load torque limit 4.5 Nm at 1 s cycle or 6.7 Nm at 2 s, operating pressure 0.3-0.8 MPa (43-116 psi), proof pressure 1.2 MPa (175 psi), temperature -20 to +70 C, minimum clamp and open time 1 s, double acting with air cushion.
K specifies the PNP electrical sensor variant; KN is the NPN version and KA the pneumatic one, while a blank means no sensor. An AirTAC clamp arm can be ordered by selecting an AM1, AM2, AM3 or AM4 code in R, C or L hole layouts, or the 105 degree opening can be altered by replacing the adjusting screw.