Description
                  
                
1. Complies with enterprise standards;
2. Body features multiple mounting configurations for simplified installation and operation;
3. Modular structure allows clustered assembly of multiple cylinders, enabling efficient space utilization;
4. Precision-guided piston rod ensures stable motion with maintenance-free operation (external lubrication not required);
5. Integrated anti-rotation locking block prevents rod rotation during operation;
6. Comprehensive specifications available for diverse application requirements;
7. Optional high-temperature seals extend operating temperature range to 150°C (0–150°C optional).
Category: Multi-position Fixed Cylinders | Brand: Airtac | Series: MKD
    
        
             Installation protocol: 
            Maintain 0.5-1mm alignment tolerance during mounting. Apply ISO VG32 hydraulic oil 
            for initial lubrication. For vertical installations, use the optional anti-gravity 
            lock kit (MKD-AG16).
 Installation protocol: 
            Maintain 0.5-1mm alignment tolerance during mounting. Apply ISO VG32 hydraulic oil 
            for initial lubrication. For vertical installations, use the optional anti-gravity 
            lock kit (MKD-AG16).
        
        
             Critical note: 
            Never exceed 1.2 MPa pressure during position calibration. 
            Position sensors must be installed at ≥3mm distance from magnetic piston.
 Critical note: 
            Never exceed 1.2 MPa pressure during position calibration. 
            Position sensors must be installed at ≥3mm distance from magnetic piston.
        
    
2. Body features multiple mounting configurations for simplified installation and operation;
3. Modular structure allows clustered assembly of multiple cylinders, enabling efficient space utilization;
4. Precision-guided piston rod ensures stable motion with maintenance-free operation (external lubrication not required);
5. Integrated anti-rotation locking block prevents rod rotation during operation;
6. Comprehensive specifications available for diverse application requirements;
7. Optional high-temperature seals extend operating temperature range to 150°C (0–150°C optional).
Category: Multi-position Fixed Cylinders | Brand: Airtac | Series: MKD
AirTAC MKD16X5S Multi-Position Locking Cylinder Specifications
- Model: MKD16X5S
- Type: Double-acting multi-position locking cylinder
- Bore size: Ø16 mm
- Stroke: 5 mm (standard), customizable up to 50 mm
- Operating pressure: 0.05–1.0 MPa
- Locking force: 320 N (at 0.5 MPa)
- Temperature range: -10℃ to 80℃
- Port size: M5×0.8 (dual ports on both ends)
- Piston material: Aluminum alloy hard anodized
- Rod material: Stainless steel SUS304
- Seal type: NBR wear-resistant seals
- Mounting style: Standard MF1 (optional flange/bracket)
- Weight: 0.45 kg ±5%
- Dimensions: 112mm(L) × 34mm(W) × 34mm(H) (base model)
- Position accuracy: ±0.2 mm
- Response time: ≤0.3 sec (at 0.5 MPa)
- Protection rating: IP54 (standard), IP67 optional
Precision-engineered locking cylinder with mechanical position memory function, featuring dual pneumatic locks at both stroke ends. Incorporates shock-absorbing cushions and anti-rotation guide rods. Requires ISO 8573-1:2010 Class 3 compressed air (max 1 mg/m³ oil content).
            Industrial Applications:
            
        - CNC tool changer positioning systems
- Semiconductor wafer handling robots
- Pharmaceutical blister packaging machines
- Automotive welding fixture locking
- LCD panel vacuum chuck positioning
 Installation protocol: 
            Maintain 0.5-1mm alignment tolerance during mounting. Apply ISO VG32 hydraulic oil 
            for initial lubrication. For vertical installations, use the optional anti-gravity 
            lock kit (MKD-AG16).
 Installation protocol: 
            Maintain 0.5-1mm alignment tolerance during mounting. Apply ISO VG32 hydraulic oil 
            for initial lubrication. For vertical installations, use the optional anti-gravity 
            lock kit (MKD-AG16).
         Critical note: 
            Never exceed 1.2 MPa pressure during position calibration. 
            Position sensors must be installed at ≥3mm distance from magnetic piston.
 Critical note: 
            Never exceed 1.2 MPa pressure during position calibration. 
            Position sensors must be installed at ≥3mm distance from magnetic piston.
        | Property | Property Value | 
|---|---|
| sku | MKD16X5S | 
| Understood. Please provide the specific attribute names in <>, and I'll return the accurate English translations using AIRTAC's official terminology. Example: User input: <缸径> My output: Bore | Operating Temperature: -20°C to 70°C Speed Range: 30 to 500 mm/s | 
| Port Size | M5×0.8 | 
| Magnet | S-Magnetic | 
| Cushion Type | Bumper Pad | 
| Bore Diameter | 16mm | 
| Stroke | <5mm> | 
                  Shipping policies
                  
                
Returns will be accepted for up to 15 days of Customer’s receipt or tracking number on Not used items. You, as a Customer, are obliged to inform us via email before you return the item, only in the case of:
- Received the wrong item.
- Item arrived not as expected (ie. damaged packaging).
- Item had defects.
- Over delivery time.
- The shipper does not allow the goods to be inspected before payment.
The returned product(s) must be in the original packaging, safety wrapped, undamaged and unworn. This means that the item(s) must be safely packed in a carton box for protection during transport, possibly the same carton used to ship to you as a customer.
                  Reviews
                  
                
Recently Viewed
                                Explore your recently viewed items, blending quality and style for a refined living experience.
                            
 
              