verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC PTL Series · Push-lock speed controller, threaded elbow

Airtac PTL Exhaust Throttle Type Speed Control Valve PTL601AD

The AirTAC Airtac PTL Exhaust Throttle Type Speed Control Valve PTL601AD is a genuine push-lock speed controller, threaded elbow with push-lock adjusting cap (pom) and fixed tube direction, used to set the speed of a pneumatic cylinder by throttling its air.

  • TypePush-lock speed controller, threaded elbow
  • SeriesPTL
  • Working pressure0 - 1.0 MPa (0 - 10 kgf/cm2)
  • Proof pressure1.5 MPa
  • AdjustmentPush-lock adjusting cap (POM)
  • Temperature-20 to +70 °C
$9.43 $13.36Save 29% Standard part — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every PTL tube size, thread and version on one page All PTL codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac PTL Exhaust Throttle Type Speed Control Valve PTL601AD

The PTL601AD is a push-lock speed controller that meters air from the 1/8in PT thread port out to the Dia 6 tube, while air travelling the opposite way passes through the brass throttling column unrestricted. That meter-out arrangement is the first choice for a solenoid valve driving a double-acting cylinder: throttling the exhaust leaves a back-pressure cushion behind the piston, so the stroke stays smooth instead of lurching under changing load. The handle is marked A to confirm meter-out.

Unlike the knob-and-locknut PSL, this version uses a push-lock cap: press the black cap in, turn it to set the speed, and release. The POM cap grips the adjustment and resists being knocked off position by vibration or an operator brushing past, which is why push-lock parts are favoured on mobile fixtures and tightly packed panels. The D suffix means the standard grey body is supplied in black. Torque the 1/8in push-lock cap to 0.08 N.m when fitting so the seal seats without cracking the POM.

Airtac PTL Exhaust Throttle Type Speed Control Valve PTL601AD Technical Specifications

ModelAirtac PTL Exhaust Throttle Type Speed Control Valve PTL601AD
TypePush-lock speed controller, threaded elbow
SeriesPTL
AdjustmentPush-lock adjusting cap (POM)
OrientationFixed tube direction
Working pressure0 - 1.0 MPa (0 - 10 kgf/cm2)
Negative pressure-750 mmHg (10 Torr)
Proof pressure1.5 MPa
Temperature-20 to +70 °C
Applicable tubingSoft nylon or polyurethane tube
Thread standardPT (Rc tapered) unless the code says otherwise

POM release button and chuck, aluminium-alloy guide, stainless spring gasket, NBR O-ring; body brass or PBT depending on the part. A speed controller is not a shut-off valve - a small leak past a fully closed needle is normal. Close it before applying air, and turn it open slowly. AirTAC publishes flow as a characteristic curve rather than a single figure, so no L/min value is listed.

Model Code: Airtac PTL Exhaust Throttle Type Speed Control Valve PTL601AD

PTLPush-lock speed controller, threaded elbow.
4 / 6 / 8 / 10 / 12Tube outside diameter in mm (3.2 mm exists on the mini series).
M5 / 01 / 02 / 03 / 04Thread: M5x0.8, 1/8", 1/4", 3/8", 1/2" (M3 on the mini series).
A / BA = meter-out (controls flow from the thread port to the tube). B = meter-in.
DBlack. Blank = grey.

Meter-Out or Meter-In?

  • check Meter-out (A) is the default. It throttles the air LEAVING the cylinder, so the piston runs against a back-pressure cushion and moves smoothly.
  • check Use meter-out on double-acting cylinders - it is the one AirTAC lists as first priority.
  • check Meter-in (B) throttles air ENTERING the cylinder. It suits single-acting cylinders and air motors.
  • check Meter-in on a double-acting cylinder tends to give a jerky, stick-slip stroke under varying load.
  • check Fit the controller at the cylinder port, not at the valve, so the throttled volume is as small as possible.

Where the Airtac PTL Exhaust Throttle Type Speed Control Valve PTL601AD Is Used

precision_manufacturing

PCB pick-and-place gantry

A Dia 6 circuit on a small electronics gantry lowering a vacuum head onto a populated board: meter-out control keeps the descent from slamming and cracking components, and the black body reads clean against dark machine framing.

tune

Carton flap clamp on a packaging line

A clamp cylinder that presses a carton flap before gluing benefits from push-lock adjustment: staff set the gentle closing speed once, and the locked cap survives the constant vibration of the packaging machine without drifting.

conveyor_belt

Bottle indexing pusher

On a bottling conveyor, an index pusher timed between bottle carriers needs a repeatable stroke speed every cycle; a Dia 6 meter-out controller at the cylinder port gives that timing without extra throttling hardware downstream.

Is the Airtac PTL Exhaust Throttle Type Speed Control Valve PTL601AD the Right Part?

Confirm the control direction first. If your valve drives a double-acting cylinder and you want the stroke cushioned, meter-out PTL601AD is correct; for a single-acting spring-return cylinder, take the meter-in PTL601B instead, since meter-in on a double-acting cylinder tends to stick-slip as load varies. Note that the tube outlet is fixed on the PTL body - it does not swivel. If you need the elbow to rotate to meet the tube run, that is the PTS family.

On size: Dia 6 is the smallest tube on the PTL 1/8in ladder, so there is no Dia 4 here - the mini PTL-M covers Dia 4 in M5 and 1/8in. One step up is PTL801A with Dia 8 tube for actuators that move more air per cycle. The same Dia 6 tube is also offered with a 1/4in thread as PTL602A if your valve or cylinder port is the larger size. Fit the controller directly at the cylinder port so only the short stub of tube is throttled and response stays crisp.

Quick checklist

  • ✓ Tube outside diameter matches exactly
  • ✓ Thread size and standard match the port
  • ✓ Working pressure within 0 - 1.0 MPa (0 - 10 kgf/cm2)
  • ✓ Temperature within -20 to +70 °C
  • ✓ Meter-out (A) unless you know you need meter-in
Ask an Engineer

Airtac PTL Exhaust Throttle Type Speed Control Valve PTL601AD FAQ

This is a Dia 6 tube, 1/8in PT thread push-lock speed controller in black. Working pressure 0-1.0 MPa (0-10 kgf/cm2), proof pressure 1.5 MPa, negative pressure down to -750 mmHg (10 Torr), and a temperature range of -20 to +70 C. It is rated for soft nylon or polyurethane tubing. Flow is published by AirTAC as a characteristic curve rather than a Cv or L/min figure.

Press the black POM cap in to release the adjustment, turn it to throttle the meter-out direction, then let go - the cap locks itself. AirTAC specifies a tightening torque for the push-lock cap, and on the 1/8in thread of this model it is 0.08 N.m. Do not use the controller as a shut-off: it is designed to leak slightly when fully closed, so use a PHV finger valve if the circuit needs true isolation.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard parts are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac PTL Exhaust Throttle Type Speed Control Valve PTL601AD

Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for PTL601AD and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.