The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF100X900S-10B is a genuine double-acting ISO 15552 cylinder with a Ø100mm bore, 900mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF100X900S-10B is a double-acting ISO 15552 profile cylinder featuring an integrated 4M310-10 5/2 solenoid valve. This built-in valve provides an effective flow area of 30.0 mm2 (Cv 1.68) and operates at a maximum frequency of 4 cycles per second. Equipped with a DC24V terminal coil drawing 3.0 W, it achieves an IP65 rating and activates in 0.05 seconds or less. The cylinder features a carbon steel piston rod and includes a magnet for CMSE reed and DMSE electronic sensors.
Because the cylinder body rates to 1.0 MPa but the internal pilot valve operates at 0.15-0.8 MPa, the practical working range for this assembled unit is 0.15-0.8 MPa. At 0.5 MPa it generates 3927 N of push force and 3681 N of pull force. The factory setting retracts the rod when the coil is energised, but you can reconfigure it to extend-when-energised by repositioning the valve. The manifold connects to the cylinder via PU tubing (O10 x O6.5), and the valve port (3/8") differs from the cylinder port (1/2").
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF100X900S-10B |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø100 mm |
| Stroke | 900 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/2 |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 3927 N | 3682 N |
| 0.7 MPa | 5498 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 100×900 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large-scale automated machinery where running individual valve tubing back to a central manifold is costly and complex.
Provides robust 3927 N of push force at 0.5 MPa for securing heavy workpieces during machining operations.
Integrates the 4M310 valve directly on the profile body, saving valuable panel space and simplifying machine upgrades.
Choose this 100mm bore when you need high thrust, such as 3927 N at 0.5 MPa, and want to eliminate remote valve plumbing. If your application requires less force, stepping down to an 80mm bore yields 2513 N of push force at 0.5 MPa. This self-valved unit excels in decentralized stations across large machines, saving panel space and wiring by driving the cylinder directly from one DC24V coil signal. For load-holding applications, note that neither the 5/2 valve nor the air cushions act as a lock; consider the SAIL series for mechanical locking needs.
When replacing this unit, match the 100mm bore, 900mm stroke, 3/8" valve port, DC24V voltage, terminal entry, PT thread, and the -S magnet. Since the stroke is 900mm, ensure adequate guide support to prevent excessive side loads on the piston rod.
Quick checklist
At 0.5 MPa operating pressure, this 100mm bore cylinder generates 3927 N of push force and 3681 N of pull force. The integrated 4M310-10 valve provides an effective flow area of 30.0 mm2 (Cv 1.68) to drive these high loads.
You do not need a separate valve. The built-in 4M310 5/2 solenoid valve switches the cylinder directly from a DC24V terminal coil signal. By default, the piston rod retracts when the coil is energised, but you can reconfigure it to extend-when-energised by repositioning the valve.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.