The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF32X160S-06E is a genuine double-acting ISO 15552 cylinder with a Ø32mm bore, 160mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF32X160S-06E is a double-acting ISO 15552 profile cylinder featuring an integrated 4M210-06 5/2 solenoid valve. This specific SKU utilizes a 1/8" valve port (code 06) paired with a PT 1/8" cylinder port, manifolded via an O8 x O5 PU tube. Driven by an AC24V terminal entry coil consuming 3.5 VA, it activates in 0.05 s or less with an IP65 rating. Because the valve operates at 0.15-0.8 MPa, this defines the practical working pressure for the assembled unit, even though the bare cylinder rates to 1.0 MPa.
Delivering 402 N of push force at 0.5 MPa, this 32 mm bore unit is designed for decentralized installations. By switching itself from a single coil signal, it eliminates remote valves and reduces panel plumbing. The factory setting retracts the piston rod when the coil is energised, but you can reposition the valve to extend-when-energised. This -S variant includes a magnet for CMSE reed and DMSE electronic sensors.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF32X160S-06E |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø32 mm |
| Stroke | 160 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/8 |
| Rod thread | M10×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | AC24V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 402 N | 346 N |
| 0.7 MPa | 563 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 32×160 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| E | Coil voltage AC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large machines where running air lines to a central manifold is costly, providing localized 5/2 valve control directly on the 32 mm cylinder.
The integrated valve manifold saves panel space while delivering 402 N of push force at 0.5 MPa for precise component positioning.
Perfect for upgrading existing lines with self-switching logic, using the standard ISO 15552 mounting interface and a PT 1/8" port.
Choose this self-valved SAIF model when machine layout demands localized control over a separate cylinder and remote valve setup, significantly cutting tubing and wiring costs. If your application requires greater thrust, stepping up to the 40 mm bore yields 628 N of push force at 0.5 MPa. Keep in mind that the 5/2 valve routes air but does not lock the load; for position holding under pressure loss, consider the SAIL lock series. For stroke lengths of 300 mm or more, ensure external guide rails are used to manage side loads.
When specifying a replacement, match the 32 mm bore, 160 mm stroke, 1/8" valve port, PT 1/8" cylinder port, AC24V terminal coil, and the -S magnet option exactly. The integrated valve achieves a 14.0 mm2 effective area (Cv 0.78) and a maximum frequency of 5 cycles per second.
Quick checklist
The 32 mm bore generates 402 N of push force at 0.5 MPa and 724 N at 0.9 MPa. The built-in 4M210-06 valve provides an effective area of 14.0 mm2 (Cv 0.78).
It uses an AC24V terminal entry coil (3.5 VA, IP65). The factory setting retracts the rod when energised, but the 5/2 valve can be repositioned to extend-when-energised, eliminating the need for a separate remote valve.