The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF32X200S-06A is a genuine double-acting ISO 15552 cylinder with a Ø32mm bore, 200mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF32X200S-06A is a double-acting ISO 15552 profile cylinder featuring an integrated 4M210-06 5/2 solenoid valve. This built-in valve provides a Cv of 0.78 and eliminates the need for remote plumbing, using an O8 x O5 PU tube to connect the manifold block to the cylinder. Driven by an AC220V terminal-entry coil that consumes 3.5 VA, it activates in 0.05 s. Because the valve operates at 0.15-0.8 MPa, this defines the practical working pressure for the assembled unit, even though the bare cylinder rates to 1.0 MPa.
At 0.5 MPa, the 32mm bore generates 402N of push force and 345N of pull force. The factory default setting retracts the piston rod when the coil is energised, but you can reposition the valve to extend-when-energised if your logic requires it. Equipped with a magnet (-S), it supports CMSE reed and DMSE electronic sensors for position feedback.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF32X200S-06A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø32 mm |
| Stroke | 200 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/8 |
| Rod thread | M10×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 402 N | 346 N |
| 0.7 MPa | 563 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 32×200 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large machines where running individual valve tubing back to a central island is costly; one AC220V signal directly drives this 32mm cylinder.
Fits space-tight machinery by combining the actuator and 4M210 valve into one package, saving valuable mounting envelope.
Simplifies upgrades on existing lines where adding external pneumatic plumbing is impractical, offering 402N push force at 0.5 MPa.
Choose this self-valved SAIF32X200S-06A when you need decentralized control across a large machine without dedicating panel space to a separate valve island. The integrated 4M210 valve handles up to 5 cycles per second. If your application requires greater thrust, stepping up to the 40mm bore yields 628N of push force at 0.5 MPa. Conversely, if you need load holding or failsafe locking, this 5/2 valve only routes air and cannot hold position without live pressure; consider the SAIL lock cylinder instead.
With a 200mm stroke, ensure adequate guiding to prevent excessive side loads on the rod. When ordering a replacement, verify the 32mm bore, 200mm stroke, PT1/8 cylinder port, 4M210-06 valve port code, AC220V voltage, terminal electrical entry, and the -S magnet option.
Quick checklist
At 0.5 MPa, the 32mm bore provides 402N of push force and 345N of pull force. The maximum thrust reaches 82 kgf at 1.0 MPa, though the practical operating pressure is 0.15-0.8 MPa due to the built-in valve.
No, the 4M210-06 is an internally piloted 5/2 valve. By default, the rod retracts when the AC220V coil is energised, but it can be reconfigured to extend-when-energised by repositioning the valve.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.