The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF40X250S-06B is a genuine double-acting ISO 15552 cylinder with a Ø40mm bore, 250mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF40X250S-06B is a double-acting profile cylinder with a built-in 4M210-06 5/2 solenoid valve, delivering a 628N push force at 0.5 MPa. Driven by a DC24V terminal coil consuming 3.0 W, it switches itself from a single electrical signal. This eliminates remote valves and excess plumbing, making it ideal for decentralized machine stations. The assembly operates safely within 0.15-0.8 MPa, as the valve limits the cylinder's 1.0 MPa base rating.
By default, the piston rod retracts when the coil is energised, but you can reconfigure it to extend-when-energised by repositioning the valve. The manifold connects via an O8 x O5 PU tube, and the valve's 1/8 inch port differs from the cylinder's 1/4 inch port. Equipped with a magnet, this unit supports CMSE reed and DMSE electronic sensors for precise positioning.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF40X250S-06B |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø40 mm |
| Stroke | 250 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/4 |
| Rod thread | M12×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 628 N | 528 N |
| 0.7 MPa | 880 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 40×250 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Eliminates the need for a central valve bank by controlling the cylinder directly at the station, reducing tubing runs across large machinery.
The integrated 4M210 valve manifold saves valuable panel and footprint space where routing external valve plumbing is physically impossible.
Ideal for upgrading older pneumatic lines where adding new valve tubing is costly, requiring only a single DC24V electrical signal to operate.
Choose this self-valved SAIF unit to save panel space and wiring compared to running a separate cylinder and remote valve. If your application requires less force, stepping down to a 32mm bore yields 402N push at 0.5 MPa; for heavier loads, a 50mm bore provides 982N. This DC24V terminal entry model suits standard control panels, while the PT 1/8 valve port offers a 14.0 mm2 effective area (Cv 0.78). When ordering a replacement, match the 40mm bore, 250mm stroke, 1/8 valve port, DC24V voltage, terminal entry, PT thread, and -S magnet. For this 250mm stroke, ensure adequate guide support to handle side loads and prevent rod deflection. Note that the 5/2 valve routes air but does not lock the load; for position holding, consider a SAIL lock cylinder.
Quick checklist
The 40mm bore generates a 628N push force and 528N pull force at 0.5 MPa. The built-in 4M210-06 valve has a 14.0 mm2 effective area (Cv 0.78) and a maximum frequency of 5 cycles per second.
The 5/2 valve routes air but does not lock the load without live pressure. Factory-set to retract when the DC24V coil is energised, the valve can be repositioned to extend-when-energised. This self-contained switching removes the need for a separate remote valve.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.