The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF50X125-06A is a genuine double-acting ISO 15552 cylinder with a Ø50mm bore, 125mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF50X125-06A is a double-acting ISO 15552 profile cylinder featuring a built-in 4M210-06 5/2 solenoid valve. Driven by an AC220V terminal coil drawing 3.5 VA, it achieves a 0.05 s response time. The integrated valve provides a 14.0 mm2 effective area (Cv 0.78) and operates at 0.15-0.8 MPa, which sets the practical working range for this assembled unit since the valve limits the 1.0 MPa cylinder rating. With a 50 mm bore, it generates 982 N of push force at 0.5 MPa.
By switching itself from a single coil signal, this unit eliminates remote valves and excess tubing, making it perfect for decentralized stations across large machines. The manifold connects to the cylinder via O8 x O5 PU tubing, and the factory setting retracts the rod when the coil is energised. You can reposition the valve to extend-when-energised if your sequence requires it. The standard carbon steel rod and PT tapered threads ensure robust pneumatic sealing.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF50X125-06A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø50 mm |
| Stroke | 125 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G1/4 |
| Rod thread | M16×1.5 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 982 N | 825 N |
| 0.7 MPa | 1374 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 50×125 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Eliminates the need for a central valve manifold on large equipment by switching locally via the AC220V terminal coil, drastically reducing tubing runs.
Fits into tight cell layouts where running separate valve tubing is costly, delivering 982 N of push force with a built-in 4M210-06 valve.
Drops into existing ISO 15552 dimensionally interchangeable footprints to upgrade a standard actuator into a self-switching unit without external plumbing.
Choose this 50 mm bore when you need around 982 N of thrust at 0.5 MPa; step down to a 40 mm bore (628 N push) for lighter loads, or up to a 63 mm bore (1559 N push) if you need substantially more force. A self-valved SAIF beats a separate cylinder and remote valve in space-tight machines by cutting panel space and wiring. The 4M210-06 valve features a 1/8" port, while the cylinder port is 1/4". Remember the 5/2 valve routes air and is not a lock; the air cushion only decelerates near stroke end. For load-holding, select a SAIL lock cylinder. To replace this unit, match the 50 mm bore, 125 mm stroke, 06 valve port, AC220V terminal coil, PT threads, and no magnet.
Quick checklist
At 0.5 MPa, this 50 mm bore cylinder generates 982 N of push force and 825 N of pull force. The integrated 4M210-06 5/2 valve has an effective area of 14.0 mm2 (Cv 0.78) and a maximum frequency of 5 cycles per second.
No, the SAIF50X125-06A has a 4M210-06 valve built directly onto the manifold. It operates on AC220V with a terminal entry. By default, the rod retracts when the coil is energised, but you can reposition the valve to extend-when-energised.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.