The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF63X1000S-10A is a genuine double-acting ISO 15552 cylinder with a Ø63mm bore, 1000mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF63X1000S-10A is a double-acting ISO 15552 profile cylinder featuring an integrated 4M310-10 5/2 solenoid valve. Equipped with a magnet for position sensing, it is designed for decentralized automation where running separate valve tubing is costly. The manifold links the valve to the cylinder using PU tubing (O10 x O6.5), meaning the 3/8 inch valve port and 3/8 inch cylinder port are distinct connections that must not be confused during installation.
This assembly is driven by an AC220V terminal-entry coil drawing 3.5 VA, featuring IP65 protection and a rapid 0.05s activation time. Because the built-in valve operates at 0.15-0.8 MPa, the practical working range for the assembled SAIF unit is 0.15-0.8 MPa, even though the bare cylinder rates to 1.0 MPa. Delivering a push force of 1559N at 0.5 MPa, the factory valve setting retracts the rod when the coil is energised, but it can be reconfigured to extend-when-energised by simply repositioning the valve.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF63X1000S-10A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø63 mm |
| Stroke | 1000 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G3/8 |
| Rod thread | M16×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 1559 N | 1402 N |
| 0.7 MPa | 2182 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 63×1000 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Ideal for large factory layouts where routing individual air lines to a central valve bank is inefficient, allowing each station to control itself from one coil signal.
Suitable for long-travel material handling or lifting tasks up to 1000mm, provided external guidance is used to mitigate rod side-loading on the profile cylinder.
Perfect for machine upgrades where panel space is at a premium, integrating the 4M310 valve directly onto the cylinder to minimize the overall footprint.
Choose this self-valved SAIF63 unit to eliminate remote valve panels and drastically reduce plumbing space across large machines. If your application requires less force, stepping down to a 50mm bore yields 982N of push force at 0.5 MPa; if you need more power, an 80mm bore provides 2513N at the same pressure. For load-holding requirements, remember that neither the 5/2 valve nor the adjustable air cushions act as a brake—consider the SAIL lock cylinder or BSAI clamp-lock series instead.
When replacing this assembly, match the 63mm bore, 1000mm stroke, 3/8 inch valve port, AC220V terminal coil, PT tapered threads, and the -S magnet. Because the stroke is 1000mm, carefully manage side loads by using external guide rails to prevent rod damage and ensure smooth operation across the full travel distance.
Quick checklist
The 63mm bore generates a push force of 1559N and a pull force of 1402N at 0.5 MPa. The built-in 4M310-10 valve provides an effective flow area of 30.0 mm2 (Cv 1.68) to drive these movements.
No, the 5/2 valve routes air but does not lock the load without live pressure. By factory default, the piston rod retracts when the AC220V coil is energised; this can be changed to extend-when-energised by repositioning the valve.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.