The AirTAC Airtac SAIF Series Standard Cylinder with Valve SAIF63X150S-10A is a genuine double-acting ISO 15552 cylinder with a Ø63mm bore, 150mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The AirTAC SAIF63X150S-10A is a double-acting ISO 15552 profile cylinder equipped with a built-in 4M310-10 5/2 solenoid valve. Delivering a Cv of 1.68 and a 30 mm2 effective orifice, the integrated valve manifold uses O10 x O6.5 PU tubing to drive the 63 mm bore. It generates 1559 N of push force at 0.5 MPa. This specific SKU features a PT3/8 cylinder port, a PT3/8 valve port, an AC220V terminal coil drawing 3.5 VA, and an -S magnet for CMSE or DMSE position sensing.
Because the built-in valve operates at 0.15-0.8 MPa, the practical working range for the assembled SAIF unit is 0.15-0.8 MPa, even though the bare cylinder rates to 1.0 MPa. The factory setting retracts the carbon steel piston rod when the coil energises, but you can reposition the valve to extend-when-energised. It switches itself from one coil signal, eliminating remote plumbing and making it ideal for decentralized machine stations.
| Model | Airtac SAIF Series Standard Cylinder with Valve SAIF63X150S-10A |
|---|---|
| Series | SAIF ISO 15552 cylinder with valve |
| Bore size | Ø63 mm |
| Stroke | 150 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | G3/8 |
| Rod thread | M16×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAIF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAIF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 1559 N | 1402 N |
| 0.7 MPa | 2182 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAIF | ISO 15552 cylinder with built-in 4M valve. |
|---|---|
| 63×150 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAIF does not hold its load without air — the valve routes air, it is not a lock. For load-holding use a SAIL (lock) or BSAI (clamp-lock).
Eliminates the need for long valve tubing runs by integrating the 4M310 valve directly on the 63 mm cylinder for localized control.
Saves valuable panel space by removing the remote valve bank, driving the 1559 N push load directly from a single AC220V terminal signal.
Ideal for upgrading existing ISO 15552 machines where running new pneumatic tubing to a central manifold is costly and complex.
Choose this 63 mm bore when a 50 mm bore (982 N push at 0.5 MPa) is insufficient, but a 80 mm bore (2513 N push at 0.5 MPa) would be excessive. A self-valved SAIF beats a separate cylinder plus a remote valve when you need to minimize panel space and wiring across decentralized stations. For load-holding applications, note that the 5/2 valve routes air but does not lock the load; consider AirTAC SAIL or BSAI for clamp-lock requirements. At 150 mm stroke, side-load is moderate, but always ensure proper guide alignment to prevent premature seal wear.
When ordering a replacement, verify the 63 mm bore, 150 mm stroke, PT3/8 valve port, AC220V voltage, terminal electrical entry, PT thread standard, and the -S magnet option. The valve max frequency is 4 cycles per second, and the coil responds in 0.05 s with IP65 protection.
Quick checklist
The 63 mm bore generates 1559 N push and 1402 N pull force at 0.5 MPa. The built-in 4M310-10 valve provides a 30 mm2 effective area (Cv 1.68) for optimal air flow.
The built-in 5/2 valve allows the cylinder to switch itself from one AC220V coil signal without a separate remote valve. By factory default, the rod retracts when energised, but you can reposition the valve to extend-when-energised.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.