The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X100-06A is a genuine double-acting profile-type cylinder with a Ø32mm bore, 100mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF32X100-06A is a double-acting profile cylinder with a built-in AirTAC 4M210 5/2 solenoid valve on the cap. One coil signal drives the actuator, eliminating remote plumbing and saving a manifold slot. The extruded aluminum barrel makes it shorter than an ISO 15552 cylinder of the same bore. This 32mm bore pushes 402N and pulls 345N at 0.5 MPa, operating safely within the valve's 0.15-0.8 MPa range.
The integrated 4M210-06 valve has a 1/8" port, Cv 0.78 flow, and handles 5 cycles/sec. It uses an AC220V terminal-entry coil rated IP65. Computed buyer insight: safe working load is roughly 241N (60% of the 0.5 MPa push force), with a vertical lift capacity around 20kg at a 2:1 margin. The cylinder body rates to 1.0 MPa, but the assembled unit is limited by the 0.15-0.8 MPa valve window. This SKU lacks a magnet and cannot accept a sensor.
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X100-06A |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø32 mm |
| Stroke | 100 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 1/8" |
| Rod thread | M10×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 402 N | 346 N |
| 0.7 MPa | 563 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 32×100 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Ideal for distributed machining cells where running individual air lines to a central manifold is impractical, letting each clamp fire from a single local coil signal.
Fits into tight machine frames to push small parts off a conveyor, using the integrated 4M210 valve to eliminate extra tubing between the actuator and a remote valve bank.
Perfect for modular assembly lines where each diverter gate operates independently, saving manifold slots and simplifying pneumatic wiring across a large factory floor.
Size by force: this 32mm bore pushes 402N at 0.5 MPa; step up to the 40mm bore (628N) if your load exceeds the safe working load of 241N, or down to a smaller profile cylinder for lighter duties. Confirm the AC220V terminal entry matches your supply. The rod retracts when the coil is energised, but you can reposition the valve to extend on signal. Always size within the 0.15-0.8 MPa valve limit, not the 1.0 MPa cylinder body rating. The built-in valve routes air and is not a lock; add an external rod lock or pilot-operated check valve to hold a load. For this 100mm stroke, side-load is minimal, but for strokes >=300mm use a guide to prevent rod binding.
Quick checklist
It delivers 402N push and 345N pull at 0.5 MPa. The built-in valve is a 4M210-06 (1/8" port, Cv 0.78, 5 cycles/sec) with an AC220V terminal-entry coil. Although the cylinder body rates to 1.0 MPa, the assembled unit must operate within the 0.15-0.8 MPa valve window. The cylinder air port is 1/8".
By default the rod retracts when the coil is energised, but you can reposition the valve to extend on signal. The valve only routes air; it is not a load lock. If air is lost, the piston drifts and the cushion only decelerates near stroke end. Use an external rod lock or pilot-operated check valve for load holding.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.