verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC SAUF Series · Profile Cylinder with Valve

Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X125S-08B

The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X125S-08B is a genuine double-acting profile-type cylinder with a Ø32mm bore, 125mm stroke and a built-in 4M210-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.

  • BoreØ32 mm
  • Stroke125 mm
  • Built-in valve4M210-08
  • Valve port1/4"
  • CoilDC24V
  • EntryTerminal
$95.81 $103.31Save 7% Usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X125S-08B

The AirTAC SAUF32X125S-08B is a double-acting profile cylinder with a built-in 4M210 5-port 2-position solenoid valve on the cap. One DC24V coil signal drives the actuator, eliminating remote plumbing and saving a manifold slot. The extruded aluminum barrel makes it shorter than an ISO 15552 unit of the same bore. It features a 1/8" cylinder port, an M10x1.25 rod thread, and adjustable 21mm cushions.

Size force within the 0.15-0.8 MPa valve window, where it delivers 402N push and 345N pull at 0.5 MPa. The integrated 4M210-08 valve has a 1/4" port, Cv 0.89, and cycles up to 5 times per second. The computed safe working load is roughly 241N (about 60% of the 0.5 MPa push force), translating to a vertical lift capacity of around 20kg with a 2:1 margin. The S suffix indicates a piston magnet for CMSG/DMSG/EMSG switches.

Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X125S-08B Technical Specifications

ModelAirtac SAUF Series Valve-Mounted Air Cylinder SAUF32X125S-08B
SeriesSAUF profile cylinder with valve
Bore sizeØ32 mm
Stroke125 mm
Acting typeDouble acting, self-valved
Cylinder port1/8"
Rod threadM10×1.25
PU tubeØ8 × Ø5
Built-in valve4M210-08 (5/2)
Valve flow16.0 mm² (Cv 0.89)
Max frequency5 cycle/sec
Coil voltageDC24V · DC 3.0 W
Electrical entryTerminal · IP65 · B class
Response time0.05 s and below
Operating pressure0.15 – 0.8 MPa (valve limit)
Speed range30 – 800 mm/s

The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.

Theoretical Output Force (Ø32mm)

PressurePush forcePull force
0.5 MPa402 N346 N
0.7 MPa563 N

Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.

Model Code: Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X125S-08B

SAUFProfile cylinder with built-in 4M valve.
32×125Bore × stroke in mm.
-08Valve port 1/4" → 4M210-08.
BCoil voltage DC24V.
I / (blank)Terminal electrical entry.

SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.

Where the Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X125S-08B Is Used

precision_manufacturing

Decentralized Clamping

Ideal for independent clamping stations where running a single DC24V signal to each actuator saves tubing and eliminates a central manifold.

widgets

Compact Part Ejection

Fits into tight machine cells, using the built-in 4M210 valve to rapidly eject small parts at up to 5 cycles per second.

conveyor_belt

Independent Diverting

Perfect for decentralized conveyor diverters, allowing local switching without routing air lines back to a main control panel.

Is the Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X125S-08B the Right Choice?

When sizing, compare this 32mm bore (402N push at 0.5 MPa) against the neighbouring 40mm bore (628N push) to ensure adequate force. Confirm the DC24V terminal entry and PT threads match your control system. The default action retracts the rod when energised, but you can reposition the valve to extend on energisation. Operate strictly within the 0.15-0.8 MPa valve range, not the 1.0 MPa cylinder body rating. The integrated valve routes air and does not function as a load lock; add an external rod lock or pilot-operated check valve for suspended loads. For this 125mm stroke, side-load is minimal, but always guide the rod for longer strokes.

Quick checklist

  • ✓ Force at 0.15–0.8 MPa
  • ✓ Coil voltage matches panel
  • ✓ Terminal vs grommet entry
  • ✓ Retract- or extend-when-energised
  • ✓ Load-holding → external rod lock
Ask an Engineer

Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X125S-08B FAQ

It generates 402N push and 345N pull at 0.5 MPa. The built-in valve is a 4M210-08 (1/4" port, Cv 0.89) running on DC24V. You must size the force within the 0.15-0.8 MPa operating window of the valve, even though the cylinder body rates to 1.0 MPa.

By default, the rod retracts when the coil is energised. You can reconfigure it to extend when energised simply by repositioning the valve on the cap. This self-switching design means no remote valve is needed.

Related AirTAC Cylinders & Valves

Request a Quote for Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X125S-08B

Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for SAUF32X125S-08B and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.