The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X350S-06A is a genuine double-acting profile-type cylinder with a Ø32mm bore, 350mm stroke and a built-in 4M210-06 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF32X350S-06A is a double-acting profile cylinder with a built-in AirTAC 4M210-06 5/2 solenoid valve. One coil signal drives the actuator, eliminating remote plumbing and saving a manifold slot. The extruded aluminum barrel is shorter than an ISO 15552 unit of the same bore. The -S suffix means a piston magnet is present for CMSG/DMSG/EMSG switches.
Operating in the 0.15-0.8 MPa valve window, it delivers 402 N push at 0.5 MPa. The 1/8" valve port flows 14 mm2 (Cv 0.78) at up to 5 cycles/s. The bore dictates a 1/8" cylinder port with an M10x1.25 rod thread. For sizing, the safe working load is roughly 241 N, and vertical lift is about 20 kg with a 2:1 margin.
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF32X350S-06A |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø32 mm |
| Stroke | 350 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 1/8" |
| Rod thread | M10×1.25 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M210-06 (5/2) |
|---|---|
| Valve flow | 14.0 mm² (Cv 0.78) |
| Max frequency | 5 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 402 N | 346 N |
| 0.7 MPa | 563 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 32×350 | Bore × stroke in mm. |
| -06 | Valve port 1/8" → 4M210-06. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Ideal for a machining cell where each clamping station uses one coil signal, saving manifold space and tubing runs.
Switches a divert gate directly at the conveyor frame without routing air lines back to a central valve bank.
Deploys a stop arm on a packaging line; the integrated valve ensures fast local response up to 5 cycles/s.
Size by comparing neighbours: the 32 mm bore gives 402 N push at 0.5 MPa, while stepping up to 40 mm yields 628 N. Confirm the AC220V terminal entry and PT threads. Default action retracts the rod when energised, but repositioning the valve extends it. The assembled unit must operate within the 0.15-0.8 MPa valve range, not the 1.0 MPa cylinder body rating. The built-in valve routes air and is not a lock; add an external rod lock or pilot-operated check valve to hold loads. For the 350 mm stroke, use external guides to prevent rod bending and side-load wear.
Quick checklist
It pushes 402 N and pulls 345 N at 0.5 MPa. The built-in valve is a 4M210-06 (1/8" port, Cv 0.78, 5 cycles/s) with an AC220V terminal coil. Size force within the 0.15-0.8 MPa valve operating window, as the assembled unit cannot use the 1.0 MPa cylinder body rating.
By default the rod retracts when the coil is energised, but you can reposition the valve to extend on signal. The valve only routes air; it is not a load lock. The piston will drift on air loss, so fit an external rod lock or pilot-operated check valve if you need to hold a load.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.