The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF63X100S-08B is a genuine double-acting profile-type cylinder with a Ø63mm bore, 100mm stroke and a built-in 4M310-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF63X100S-08B is a double-acting profile cylinder with a built-in AirTAC 4M310 5/2 solenoid valve on the cap. One DC24V coil signal drives the actuator, eliminating remote plumbing and saving a manifold slot. The 63mm bore delivers 1559N push and 1402N pull at 0.5MPa. The cylinder body rates to 1.0MPa, but the assembled unit operates strictly within the 0.15-0.8MPa valve window.
The integrated valve provides 1/4" porting with a 25mm2 flow (Cv 1.4) and cycles up to 4 times per second. It includes a piston magnet for CMSG/DMSG/EMSG switches. For sizing, the safe working load is roughly 935N (about 60% of the 0.5MPa push force), translating to a vertical lift capacity of approximately 79kg with a 2:1 margin. The cylinder features a 3/8" air port, an M16x1.5 rod thread, and adjustable cushions.
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF63X100S-08B |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø63 mm |
| Stroke | 100 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 3/8" |
| Rod thread | M16×1.5 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M310-08 (5/2) |
|---|---|
| Valve flow | 25.0 mm² (Cv 1.40) |
| Max frequency | 4 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 1559 N | 1402 N |
| 0.7 MPa | 2182 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 63×100 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M310-08. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Ideal for a machining cell where each clamp needs its own DC24V signal without running tubing back to a central manifold.
Uses the built-in 4M310 valve to actuate a sorting gate directly at the lane, saving space and simplifying installation.
Perfect for lifting a 79kg pallet load in a compact zone, utilizing the integrated magnet for position feedback.
Size by comparing neighbouring bores: the 50mm bore offers 982N push at 0.5MPa, while the 80mm bore provides 2513N. This 63mm unit outputs 1559N push at 0.5MPa. Always size force within the 0.15-0.8MPa valve operating range, never the 1.0MPa cylinder body rating. Confirm the DC24V terminal entry and PT thread match your control setup. The default action retracts the rod when energised, but you can reconfigure it to extend by repositioning the valve. Because the valve only routes air, add an external rod lock or pilot-operated check valve for load holding. For this 100mm stroke, side-load guides are not strictly required but ensure standard SC-series mounting accessories are used.
Quick checklist
It delivers 1559N push and 1402N pull at 0.5MPa. The built-in valve is a 4M310-08 (1/4" port, Cv 1.4, 4 cycles/s max) driven by a DC24V terminal coil. Although the cylinder body rates to 1.0MPa, the assembled unit must operate within the 0.15-0.8MPa valve window.
No, the built-in valve only routes air and is not a lock. The default action retracts the rod when energised, which can be reconfigured to extend by repositioning the valve. For load holding on air loss, install an external rod lock or pilot-operated check valve.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.