The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF63X600S-10B is a genuine double-acting profile-type cylinder with a Ø63mm bore, 600mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF63X600S-10B is a double-acting profile cylinder with a built-in AirTAC 4M 5/2 solenoid valve on the cap. One coil signal drives the actuator, eliminating remote plumbing and saving a manifold slot. The extruded aluminum barrel is shorter than an ISO 15552 cylinder of the same bore. This 63mm bore unit has a 3/8" air port, an M16x1.5 rod thread, and a 600mm stroke with a piston magnet for CMSG/DMSG/EMSG switches.
It integrates a 4M310-10 valve (3/8" port, Cv 1.68, 30 mm2 flow) running at up to 4 cycles/sec. The coil is DC24V with terminal entry. Size force within the valve's 0.15-0.8 MPa window, even though the cylinder body rates to 1.0 MPa. At 0.5 MPa it pushes 1559 N and pulls 1402 N. A computed buyer insight: safe working load is roughly 935 N (about 60% of the 0.5 MPa push force), allowing a vertical lift of approximately 79 kg with a 2:1 margin.
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF63X600S-10B |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø63 mm |
| Stroke | 600 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 3/8" |
| Rod thread | M16×1.5 |
| PU tube | Ø8 × Ø5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | DC24V · DC 3.0 W |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 1559 N | 1402 N |
| 0.7 MPa | 2182 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 63×600 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| B | Coil voltage DC24V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Mounts directly at the divert gate on a long conveyor line. The integrated DC24V valve switches the 600mm stroke locally, eliminating long tubing runs back to a central manifold.
Lifts packages in a multi-stage stacking cell. The 63mm bore provides a safe working load near 935 N, while the built-in piston magnet enables stack-height confirmation via reed switches.
Acts as an independent actuator for a large access door on a machine tool. The 4M310 valve handles the 3/8" port flow locally, ensuring fast gate cycles without consuming manifold space.
Size this 63mm bore against its neighbours: a 50mm bore pushes 982 N and an 80mm bore pushes 2513 N at 0.5 MPa. This model yields 1559 N push and 1402 N pull at 0.5 MPa. Confirm the DC24V coil and terminal entry suit your control system. The cylinder body rates to 1.0 MPa, but you must size force within the built-in valve's 0.15-0.8 MPa operating window. By default the rod retracts when the coil is energised; you can reconfigure it to extend-when-energised by repositioning the valve. The valve routes air and is not a lock; for load holding on air loss, add an external rod lock or pilot-operated check valve. Because the 600mm stroke exceeds 300mm, use an external guide to prevent rod bending and side-load damage.
Quick checklist
It pushes 1559 N and pulls 1402 N at 0.5 MPa, reaching 2494 N at 0.8 MPa. The built-in valve is a 4M310-10 (3/8" port, Cv 1.68, 30 mm2 flow) with a DC24V coil. Although the cylinder body rates to 1.0 MPa, the assembled unit must operate within the valve's 0.15-0.8 MPa window.
By default the rod retracts when the coil is energised. You can reposition the valve to make it extend-when-energised. The 5/2 valve only routes air; it is not a load lock. If you need to hold a load on air loss, install an external rod lock or pilot-operated check valve.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.