The AirTAC Airtac SAUF Series Valve-Mounted Air Cylinder SAUF80X600-10A is a genuine double-acting profile-type cylinder with a Ø80mm bore, 600mm stroke and a built-in 4M310-10 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF80X600-10A is a double-acting profile cylinder with a built-in AirTAC 4M310 5/2 solenoid valve on the cap. One coil signal drives the actuator, eliminating remote valves and saving a manifold slot. The extruded aluminum barrel makes it shorter than an ISO 15552 unit of the same bore. This 80mm bore version uses a 3/8" cylinder port and a 3/8" valve port.
It delivers 2513N push at 0.5MPa, rising to 4021N at the 0.8MPa assembled maximum. The integrated valve flows 30mm2 (Cv 1.68) at up to 4 cycles/sec. The AC220V terminal-entry coil is IP65 rated. Computed buyer insight: safe working load is roughly 1508N (60% of the 0.5MPa push), allowing a vertical lift of about 128kg with a 2:1 margin. This SKU lacks the S magnet suffix and cannot take a magnetic switch.
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF80X600-10A |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø80 mm |
| Stroke | 600 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 3/8" |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-10 (5/2) |
|---|---|
| Valve flow | 30.0 mm² (Cv 1.68) |
| Max frequency | 4 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 2513 N | 2268 N |
| 0.7 MPa | 3519 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 80×600 | Bore × stroke in mm. |
| -10 | Valve port 3/8" → 4M310-10. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Switches a sorting diverter directly at the line using one AC220V signal, removing long tube runs back to a central manifold.
Uses the built-in 4M310 valve to raise and lower a 600mm stroke stop blade without dedicating a manifold slot to the station.
Pushes parts from a decentralized cell with 2513N force at 0.5MPa, relying on the integrated valve for simple local control.
Size by force: this 80mm bore gives 2513N push at 0.5MPa; step down to a 63mm bore for 1559N, or up to 100mm for 3927N. Always size within the 0.15-0.8MPa valve window, not the 1.0MPa cylinder body rating. Confirm the AC220V terminal entry fits your supply. The rod retracts when energised but you can reposition the valve to extend on signal. Because the 600mm stroke invites rod bending, add an external guide to handle side loads. The valve routes air but does not lock; add an external rod lock or pilot-operated check valve to hold a load on air loss.
Quick checklist
It pushes 2513N and pulls 2268N at 0.5MPa, reaching 4021N at 0.8MPa. The built-in 4M310-10 valve has a 3/8" port, Cv 1.68, and runs at 4 cycles/sec. The AC220V terminal coil is IP65. Size force within the valve's 0.15-0.8MPa range, not the 1.0MPa cylinder body limit.
By default the rod retracts when energised. You can reconfigure it to extend on signal by repositioning the built-in valve. This local switching removes the need for a remote valve, saving tubing and installation time.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.