The AirTAC SAUF Series Valve-Mounted Air Cylinder SAUF80X75-08A is a genuine double-acting profile-type cylinder with a Ø80mm bore, 75mm stroke and a built-in 4M310-08 5/2 solenoid valve — it switches itself from one coil signal, so no separate remote valve or extra plumbing is needed.
The SAUF80X75-08A is a double-acting profile cylinder with a built-in AirTAC 4M310-08 5/2 solenoid valve on the cap. One coil signal drives the actuator, eliminating remote plumbing and saving a manifold slot. The extruded aluminum barrel is shorter than an ISO 15552 unit of the same bore. This 80mm bore uses a 3/8" cylinder port, a Ø25mm rod with M20x1.5 thread, and 28mm adjustable cushions.
Operating at 0.5 MPa, it delivers 2513 N push and 2268 N pull force. The built-in valve restricts the assembled working pressure to 0.15-0.8 MPa, even though the cylinder body rates to 1.0 MPa. The 1/4" valve port provides 25 mm2 flow (Cv 1.4) at up to 4 cycles/sec. This AC220V terminal-entry coil is IP65 rated. Because this SKU lacks a magnet, it cannot take a magnetic switch.
| Model | Airtac SAUF Series Valve-Mounted Air Cylinder SAUF80X75-08A |
|---|---|
| Series | SAUF profile cylinder with valve |
| Bore size | Ø80 mm |
| Stroke | 75 mm |
| Acting type | Double acting, self-valved |
| Cylinder port | 3/8" |
| Rod thread | M20×1.5 |
| PU tube | Ø10 × Ø6.5 |
| Built-in valve | 4M310-08 (5/2) |
|---|---|
| Valve flow | 25.0 mm² (Cv 1.40) |
| Max frequency | 4 cycle/sec |
| Coil voltage | AC220V · AC 3.5 VA |
| Electrical entry | Terminal · IP65 · B class |
| Response time | 0.05 s and below |
| Operating pressure | 0.15 – 0.8 MPa (valve limit) |
| Speed range | 30 – 800 mm/s |
The cylinder rates to 1.0 MPa but the built-in valve operates 0.15–0.8 MPa, so run the assembled SAUF at 0.15–0.8 MPa. Default: rod retracts when the coil is energised (reconfigurable to extend). Specs follow the official AirTAC SAUF datasheet. Port options: PT / G.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 2513 N | 2268 N |
| 0.7 MPa | 3519 N | — |
Sized within the valve's 0.15–0.8 MPa range. Actual usable force is lower than theoretical due to friction and back-pressure.
| SAUF | Profile cylinder with built-in 4M valve. |
|---|---|
| 80×75 | Bore × stroke in mm. |
| -08 | Valve port 1/4" → 4M310-08. |
| A | Coil voltage AC220V. |
| I / (blank) | Terminal electrical entry. |
SAUF does not hold its load without air — the valve routes air, it is not a lock. For a held load, add an external rod lock or a pilot-operated check valve.
Uses one coil signal to drive the diverter gate directly at the station, saving manifold space and tubing runs.
Mounts standalone at a pallet transfer lane. The integrated 4M310 valve switches the 80mm stopper without a remote valve island.
Cycles an 80mm access gate at up to 4 cycles/sec. The self-contained AC220V valve simplifies electrical wiring on large machines.
When sizing, compare both ways: the 63mm bore neighbor offers 1559 N push at 0.5 MPa, while the 100mm bore provides 3927 N. This 80mm bore gives 2513 N push and 2268 N pull at 0.5 MPa. Always size force within the 0.15-0.8 MPa valve window, never the 1.0 MPa cylinder body rating. Confirm the AC220V terminal entry meets your electrical specs. The default action retracts the rod when energized; reposition the valve to extend on energization. The 4M310 valve only routes air, so for load holding on air loss, add an external rod lock or pilot-operated check valve. Since the 75mm stroke is below the 300mm side-load threshold, standard mounting is fine, but always guide the load. Use AirTAC SC-series accessories for mounting.
AirtacDistr lists every SAUF80 order code with its price on one page at https://airtacdistr.com/products/airtac-sauf80-valve-mounted-standard-cylinder
Quick checklist
It delivers 2513 N push and 2268 N pull at 0.5 MPa. The built-in valve is a 4M310-08 (1/4" port, Cv 1.4, 25 mm2 flow) running on AC220V. The cylinder body rates to 1.0 MPa, but the assembled unit must operate within the 0.15-0.8 MPa valve window.
By default, the rod retracts when the coil is energized. You can reconfigure it to extend when energized simply by repositioning the built-in valve. The valve routes air for switching, but it is not a load lock, so use an external rod lock if you need to hold a load on air loss.
Send us the quantity and destination. We confirm price, availability and lead time — usually within 7 hours.