The AirTAC Airtac SC40 Standard Cylinder SC40X1000STC is a genuine double-acting standard air cylinder with a Ø40mm bore and 1000mm stroke, PT1/4 air ports and adjustable end cushioning. It is used for push, pull, lift and clamp motion in industrial automation.

  • BoreØ40 mm
  • Stroke1000 mm
  • Port sizePT1/4
  • Acting typeDouble acting
  • Rod threadM12×1.25
  • CushionAdjustable, 21 mm
$111.63 $119.13Save 6% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac SC40 Standard Cylinder SC40X1000STC

The AirTAC SC40X1000STC is a double-acting single-rod pneumatic cylinder delivering 628 N of push force at 0.5 MPa (1130 N at 0.9 MPa). With a 40 mm bore and a full 1000 mm standard stroke, it suits long linear movements in packaging and material-handling machinery.

This model includes a built-in magnet (-S) for direct mounting of CMSG/DMSG/EMSG sensors, and ships with a centre trunnion (TC) plus TCM1 bracket for pivoting installation. The 16 mm diameter rod and 21 mm adjustable air cushion provide smooth deceleration, while the PT1/4 port ensures straightforward pneumatic connection.

Airtac SC40 Standard Cylinder SC40X1000STC Technical Specifications

ModelAirtac SC40 Standard Cylinder SC40X1000STC
SeriesSC standard tie-rod cylinder
Bore sizeØ40 mm
Stroke1000 mm
Acting typeDouble acting
Port sizePT1/4
Rod threadM12×1.25
FluidAir (filtered by 40µm element)
Operating pressure0.15 – 1.0 MPa
Proof pressure1.5 MPa
Temperature-20 to +70 °C
Speed range30 – 800 mm/s
CushionAdjustable, 21 mm
Max strokeUp to 1200 mm

Specifications follow the official AirTAC SC series datasheet. Operating pressure 0.15–1.0 MPa, proof pressure 1.5 MPa, temperature −20 to +70 °C. Confirm against the product label before installation. Thread options: PT (standard) / G.

Theoretical Output Force (Ø40mm)

PressurePush forcePull force
0.5 MPa628 N528 N
0.7 MPa880 N
Max (approx.)128 kgf

Actual usable force is lower than theoretical due to friction and back-pressure. Size with a safety margin.

Model Code: Airtac SC40 Standard Cylinder SC40X1000STC

SCStandard tie-rod cylinder series.
40Bore size in mm.
×1000Stroke length in mm.
-SOptional built-in magnet for sensor position sensing.

Related variants: SCD (double rod), SCJ (adjustable stroke), SCT (multi-position). Seals: TPU standard / H = Viton / N = NBR. Thread: blank = PT, G = G thread.

Where the Airtac SC40 Standard Cylinder SC40X1000STC Is Used

conveyor_belt

Long-Stroke Sorting Gates

The 1000 mm stroke and centre trunnion mount allow the cylinder to pivot and push diverters or gates across wide conveyor lines, with sensor feedback confirming position.

warehouse

Pallet Transfer Systems

Moves pallets between roller beds over a full metre of travel. The trunnion mount absorbs angular misalignment, while the 628 N force handles loaded pallets smoothly.

precision_manufacturing

Automated Gluing & Dispensing

Provides the long, steady reach needed for adhesive bead application across large panels. Magnetic sensors enable precise mid-stroke positioning for complex patterns.

Is the Airtac SC40 Standard Cylinder SC40X1000STC the Right Cylinder?

For higher force, step up to the 50 mm bore (982 N at 0.5 MPa); for a more compact build, the 32 mm bore offers 402 N. At 1000 mm stroke, the rod is fully extended well beyond the body length, so side loads must be managed with an external linear guide to prevent rod bending and premature seal wear.

To replace an existing cylinder, match five points: 40 mm bore, 1000 mm stroke, PT1/4 port thread, centre trunnion (TC) mounting with the F-SC40TC bracket, and the built-in magnet (-S) for sensor compatibility.

Quick checklist

  • ✓ Required force at your working pressure
  • ✓ Stroke and mounting space
  • ✓ Port/thread type (PT/NPT/G)
  • ✓ Magnet (-S) for sensors?
  • ✓ Side load — consider a guided cylinder
Ask an Engineer

Installation & Maintenance Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 1.0 MPa operating pressure.
  • check Avoid side load on the piston rod.
  • check Adjust end cushion screws for smooth stops.
  • check Use correct mounting accessory (FA/FB/CA/CB/LB/TC).
  • check Installation by qualified personnel per AirTAC docs.

Airtac SC40 Standard Cylinder SC40X1000STC FAQ

At 0.5 MPa, the cylinder provides 628 N push and 528 N pull force. At the maximum operating pressure of 0.9 MPa, push force reaches 1130 N. The theoretical maximum at 1.0 MPa is 128 kgf.

It is not recommended. The 16 mm rod is slender at full extension, making it vulnerable to bending under side loads. An external guide rod or rail system is essential to protect the rod bearings and ensure reliable long-term operation.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Related AirTAC SC Cylinders

Request a Quote for Airtac SC40 Standard Cylinder SC40X1000STC

Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for SC40X1000STC and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to support@airtacdistr.com with your model number.