The AirTAC Airtac TACQ Guided Rod Ultra-Thin Cylinder TACQ63X20S is a genuine double-acting GUIDED compact (JIS) cylinder — a Ø63mm bore, 20mm stroke and two guide rods with a fixing plate. The twin guides hold the platform non-rotating to within ±0.15° and carry lateral load a plain compact rod cannot, so it drives and guides a load in one unit.
The AirTAC TACQ63X20S is a double-acting JIS compact guided cylinder featuring a 63mm bore and 20mm stroke. Two chromed carbon steel guide rods and a fixing plate ensure non-rotating accuracy of ±0.15°, allowing the unit to drive and guide a load simultaneously while carrying lateral forces a plain rod cannot manage.
Drive force equals a standard ACQ of the same bore, as the twin rods add stiffness rather than thrust. At 0.5 MPa it yields 1558.6 N push and 1401.5 N pull, with a maximum push capacity of 318 kgf at 1.0 MPa. It includes a fixed NBR elastomer bumper for end-of-stroke deceleration and, with the built-in S magnet, supports both reed and solid-state sensors.
| Model | Airtac TACQ Guided Rod Ultra-Thin Cylinder TACQ63X20S |
|---|---|
| Series | TACQ JIS guided compact cylinder |
| Bore size | Ø63 mm |
| Stroke | 20 mm |
| Acting type | Double acting, guided (non-rotating) |
| Non-rotating tolerance | ±0.15° |
| Port size | PT1/4 |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Operating pressure | 0.15 – 1.0 MPa |
| Proof pressure | 1.5 MPa |
| Temperature | -20 to +70 °C |
| Speed range | 30 – 500 mm/s |
| Max standard stroke | Up to 100 mm |
Specifications follow the official AirTAC TACQ datasheet. Two guide rods carry lateral load and hold rotation to ±0.15°; do not apply reverse torque beyond the datasheet limit. Confirm against the product label before installation.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 1559 N | 1402 N |
| 0.7 MPa | 2182 N | — |
| Max (@1.0 MPa) | 318 kgf | |
Drive force equals a standard ACQ of the same bore — the guide rods add stiffness, not thrust. Keep moving mass and speed within the datasheet chart (rated at 0.5 MPa).
| TACQ | JIS compact cylinder WITH guider (non-rotating). |
|---|---|
| 63 | Bore size in mm. |
| ×20 | Stroke length in mm. |
| S | Built-in magnet for magnetic-switch sensing (omit = none). |
| thread | Blank = PT; G or NPT available. |
The guide plate replaces a separate rod-thread option. Related: ACQ (plain single rod), ACQD (double rod), ACQJ (adjustable stroke).
Drives a gripper assembly with high lateral load capacity, maintaining precise vertical alignment without twisting during component transfer.
Applies 1558.6 N of downward force at 0.5 MPa to seat electronic connectors, relying on the ±0.15° non-rotating tolerance for even contact.
Acts as a rigid blocking mechanism on a production line, absorbing side impacts thanks to the dual chromed carbon steel guide rods.
When sizing this 63mm bore actuator, compare it against the 50mm option (981.8 N push @0.5 MPa) for lighter loads, or the 80mm variant (2513.2 N push @0.5 MPa) if your application requires more thrust. A standard ACQ fits if external linear rails already provide anti-rotation, while a double-rod ACQD suits symmetrical pulling. Confirm your ordering needs: 63mm bore, 20mm stroke (within the 100mm maximum), S magnet for sensors, and PT1/4 port threads. Always verify lateral load and reverse torque limits, which decrease as stroke extends—check the official datasheet for exact values.
Quick checklist
This double-acting 63mm bore cylinder provides 1558.6 N push and 1401.5 N pull at 0.5 MPa, 2182 N push at 0.7 MPa, and a maximum push of 318 kgf at 1.0 MPa. The standard stroke limit is 100mm, and the twin guide rods ensure a non-rotating tolerance of ±0.15°.
The two chromed guide rods support lateral loads but have a maximum allowable reverse torque and mass/speed limit (charted at 0.5 MPa) that decreases with stroke length; confirm exact values from the datasheet. The included S magnet works with reed or electronic solid-state switches, and the fixed elastomer bumper decelerates near stroke end without holding the load on air loss.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.