verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC20006 G1/8 AirTAC F.R.L. Unit - 5 um Manual Drain

The AirTAC GC20006 G1/8 AirTAC F.R.L. Unit - 5 um Manual Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$70.93 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC20006 G1/8 AirTAC F.R.L. Unit - 5 um Manual Drain

The AirTAC GC20006MF2WGK is a three-piece F.R.L. combination that conditions compressed air in one assembly: a filter removes water and particulate, a regulator sets downstream pressure, and a lubricator adds oil mist for downstream tools and actuators. This configuration is the 200 size with a G1/8 (BSPP) port, a 5 um filter element (the finer of the two published grades), a manual drain on the filter bowl, an embedded square gauge reading in psi, and a reverse/check valve fitted to hold downstream pressure if the supply drops.

This is a genuine AirTAC part. The GC family spans the 200, 300, 400 and 600 sizes with a choice of ports, drain types, filter grades (40 um standard, 5 um optional), gauge scales (MPa, psi or bar) and G or NPT thread options. Max inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). We confirm flow and other datasheet figures on request.

GC20006 G1/8 AirTAC F.R.L. Unit - 5 um Manual Drain Technical Specifications

ModelGC20006 G1/8 AirTAC F.R.L. Unit - 5 um Manual Drain
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/8" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC20006 G1/8 AirTAC F.R.L. Unit - 5 um Manual Drain

GC200G-series F.R.L. combination, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/8" · 5 µm
One size upGC300
Two-unit equivalentGFC200-06
Build orderFilter → regulator → lubricator

Where the GC20006 G1/8 AirTAC F.R.L. Unit - 5 um Manual Drain Is Used

precision_manufacturing

CNC machining cell air supply

Feeding filtered, regulated and lubricated air to the tool-changer and clamping actuators on a small CNC cell, with the 5 um element guarding the machine's pilot valves and the check valve holding clamp pressure if the shop supply dips.

conveyor_belt

Packaging line cylinder supply

Conditioning the air feeding pick-and-place cylinders and sealing jaws on a packaging conveyor, where the regulator holds a steady setting for consistent cylinder speed and the lubricator keeps the cylinders running smoothly through long shifts.

factory

Assembly-station air drops

Serving a bench-mounted air drop on an assembly line that runs impact drivers and air cylinders, with the 5 um grade protecting the tools, the psi gauge giving operators a familiar readout, and the manual drain emptied during shift-start checks.

Is the GC20006 G1/8 AirTAC F.R.L. Unit - 5 um Manual Drain the Right Station?

Start with the size and port: the 200 series steps up through 300, 400 and 600 as port size and air demand grow, so match the size to the flow your line needs rather than to the pipe alone. This unit carries the 5 um element (code W); the 40 um standard grade suits general supply, while 5 um protects finer valves and instruments. The manual drain here means an operator opens the bowl drain during checks - choose automatic or differential-pressure drain if the installation is unattended. The square gauge is fitted reading in psi; MPa or bar scales and an external round gauge are alternatives. Thread is G (BSPP); PT is the catalogue standard and NPT is orderable. A mounting bracket is included.

One honest note before ordering: AirTAC publishes flow as curves, not as a single rated figure, so we do not quote a flow number here. Send us your application's air demand and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.

GC20006 G1/8 AirTAC F.R.L. Unit - 5 um Manual Drain FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not state a flow number. Send us your application's air demand and we will confirm the sizing against the datasheet on request before you order.

The M in the code selects a manual drain: an operator opens the filter bowl drain to expel collected water during routine checks. If the unit will be installed where nobody drains it regularly, the differential-pressure (default) or automatic drain variants of the same GC200 size are the better choice.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC20006 G1/8 AirTAC F.R.L. Unit - 5 um Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC20006MF2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.