The AirTAC GC20006F2WK AirTAC F.R.L. Combination, PT1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC20006F2WK is an AirTAC GC200 three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one conditioning set. This configuration is sized for 1/8 in PT ports and carries the W-grade 5 um filter element, a differential-pressure drain on the filter bowl, the standard regulator with a 0.15-0.9 MPa (20-130 psi) adjustment range, a fitted square gauge reading in psi, and a reverse/check valve. The polycarbonate bowls suit the -5 to 70 C non-freezing operating range, and the maximum inlet pressure is 1.0 MPa (145 psi). A mounting bracket is included.
This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and with choices of thread (PT standard, G and NPT as order options), drain type, filter grade (40 um standard, 5 um optional), gauge scale and check valve. Flow figures are published as curves rather than a single rating, so we confirm the datasheet and sizing figures on request before you order.
| Model | GC20006F2WK AirTAC F.R.L. Combination, PT1/8 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/8" · 5 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-06 |
| Build order | Filter → regulator → lubricator |
Conditioning the compressed air feed to a CNC machining centre's tool-changer and clamping cylinders: the 5 um element removes water and particulate before the regulator holds a set pressure for the changer circuit, while the lubricator mists oil to the actuator seals.
Feeding the pneumatic cylinders that index, stop and divert product on a packaging conveyor: filtered, regulated and lubricated air at the line drop keeps the stopper and pusher cylinders running consistently through the shift.
Supplying a bench-mounted air tool station in an assembly plant: the regulator sets a stable working pressure at the bench, the 5 um filter protects the tool's air motor from dirt and water, and the lubricator delivers oil mist for tool life.
Start with the port and size step: the GC200 size with 1/8 in PT ports suits compact supply drops, while GC300/400/600 steps up port size and flow path for larger demand - match the step to the air consumption of the downstream cylinders, valves and tools rather than to a single rated figure. Choose the filter grade: 40 um is the standard element and 5 um (code W, fitted here) protects finer downstream components. Choose the drain: differential-pressure (default, as fitted here), automatic, or manual. Choose the gauge scale - MPa, psi or bar - and whether the embedded square gauge (as here) or an optional external round gauge suits your panel. Select PT (standard), G or NPT thread when ordering, and add the bracket where wall or panel fixing is needed.
Because AirTAC publishes flow as curves rather than a single rated number, send us your application's air demand and we will confirm the correct size against the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Send us your application's air demand and we will confirm the correct size against the datasheet on request before you order.
The W code in GC20006F2WK selects the optional 5 um element in place of the 40 um standard grade. The finer grade suits downstream components that need cleaner air, such as precision valves and air tools. If your application does not need fine filtration, the 40 um standard element is the usual choice.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.