The AirTAC GC20006LC2W AirTAC F.R.L. Combination Unit, PT1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC20006LC2W is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one GC200 set. It cleans compressed air of water and particulate down to 5 um (the W fine-grade element), regulates downstream pressure with the low-pressure type regulator, and adds oil mist for air tools and cylinders. This configuration has 1/8 inch PT ports, a differential-pressure drain on the filter bowl, a fitted round gauge reading in psi, and a mounting bracket included. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part from the GC series, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, a choice of differential-pressure, automatic or manual drains, 40 um standard or 5 um fine filtration, and PT, G or NPT threads. Flow for this combination is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.
| Model | GC20006LC2W AirTAC F.R.L. Combination Unit, PT1/8 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/8" · 5 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-06 |
| Build order | Filter → regulator → lubricator |
Feeds filtered, regulated and lubricated air to the clamping and press cylinders on a small assembly bench, with the 5 um element protecting directional valves from water and fine particulate.
Supplies treated air to the pneumatic actuators on a carton-sealing or filling machine, where the lubricator keeps cylinder seals working and the low-pressure regulator suits circuits that run below standard line pressure.
Mounted on the bracket at a multi-station tool panel, it conditions the air feeding hand-held impact tools and air motors, with the psi gauge giving operators a direct pressure readout.
Size GC200 with 1/8 inch PT ports is the smallest step in the GC range; step up to GC300, GC400 or GC600 when your line needs larger ports and more flow. The 5 um (W) element suits downstream equipment that needs finer filtration than the 40 um standard element; choose the standard grade where coarser protection is enough. Drain options are differential-pressure (fitted here), automatic, or manual. The fitted round gauge reads in psi; embedded square gauges and MPa or bar scales are the other catalogue choices. PT is the standard thread, with G (BSPP) and NPT available as order options, and the mounting bracket is included with this unit.
Because flow is published as curves and not a single rating, send us your application details and we will confirm the sizing against the datasheet before you order. The exact regulation range of the low-pressure type is likewise confirmed on request.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.
AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote a flow number. Tell us your application and required flow, and we will confirm the sizing against the datasheet on request.
The L in the code marks the low-pressure type regulator, intended for circuits that run below standard line pressure. Its exact adjustment range is not published in the material we hold, so we confirm it on request. The unit still accepts up to 1.0 MPa (145 psi) inlet pressure.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.