verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC20006LF2 AirTAC F.R.L. Combination, PT1/8

The AirTAC GC20006LF2 AirTAC F.R.L. Combination, PT1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$60.09 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC20006LF2 AirTAC F.R.L. Combination, PT1/8

The AirTAC GC20006LF2 is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator, set up as one coordinated air-preparation package. This configuration is the GC200 size with PT1/8 (1/8 in) PT-thread ports. The filter element is the standard 40 um grade with a differential-pressure drain that bleeds collected condensate as the pressure differential across the bowl changes. The regulator is the low-pressure type and is fitted with an embedded square gauge scaled in psi; the lubricator feeds oil mist downstream to protect the pneumatic components it supplies. The bowls on the filter and lubricator are polycarbonate (PC), and a mounting bracket is included.

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600, with port sizes from 1/8 in up to 1 in, a choice of differential-pressure, automatic or manual drains, 40 um or 5 um (W) filtration, gauge scale options, and PT, G or NPT thread variants. Max working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.

GC20006LF2 AirTAC F.R.L. Combination, PT1/8 Technical Specifications

ModelGC20006LF2 AirTAC F.R.L. Combination, PT1/8
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/8" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC20006LF2 AirTAC F.R.L. Combination, PT1/8

GC200G-series F.R.L. combination, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/8" · 40 µm
One size upGC300
Two-unit equivalentGFC200-06
Build orderFilter → regulator → lubricator

Where the GC20006LF2 AirTAC F.R.L. Combination, PT1/8 Is Used

precision_manufacturing

Pneumatic clamping on a machining cell

Feeds the clamp-and-hold cylinders on a CNC fixture line: the filter strips water and chips-laden particulate from the shop air, the low-pressure regulator holds a steady clamp pressure, and the lubricator keeps the clamp cylinders and valves running smoothly cycle after cycle.

conveyor_belt

Packaging line actuator supply

A clean, regulated and lubricated air drop for the diverters, pushers and sealing heads on a carton or bagging conveyor, where one compact preparation point at the machine inlet protects every downstream actuator on the line.

build

Maintenance shop air drops

A point-of-use preparation set for a plant maintenance bench: filtered, pressure-controlled and lubricated air for impact tools, air cylinders and test rigs hooked up at the bench, with the included bracket mounting the set neatly at the drop.

Is the GC20006LF2 AirTAC F.R.L. Combination, PT1/8 the Right Station?

Start with the size and port: GC200 with PT1/8 ports is the smallest step in the series, so match it against the air consumption of the machine or line it will feed. Because flow is published as curves and not as a single rated number, ask us to confirm sizing against your application before ordering. The drain on this unit is the differential-pressure type (the default); automatic (A) and manual (M) drains are available if your maintenance routine suits them better. Filtration is the standard 40 um grade; specify the W option for 5 um where finer particle removal is needed. The regulator here is the low-pressure type (code L) rather than the standard type, and the fitted square gauge is scaled in psi; MPa and bar scales and an external round gauge are the other gauge choices. Thread is PT as standard, with G (BSPP) and NPT available as order options, and a mounting bracket is included.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.

GC20006LF2 AirTAC F.R.L. Combination, PT1/8 FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a rated flow, Cv or SCFM number for this unit. Tell us the air consumption of the machine or line you want to feed and we will confirm the sizing against the datasheet curves on request before you order.

The L in GC20006LF2 marks the low-pressure type of regulator rather than the standard type, so this unit is the version to specify where the downstream equipment is regulated at lower pressures. The exact adjustment range for the low-pressure type is not published in our sheet, so ask us to confirm it on request. Standard-type GC units and other gauge scales (MPa or bar) are also available.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC20006LF2 AirTAC F.R.L. Combination, PT1/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC20006LF2 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.