The AirTAC GC20006MC2W AirTAC F.R.L. Combination, PT1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The GC20006MC2W is an AirTAC GC three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one 3-piece set. This size 200 configuration has PT1/8 ports, a 5 um filter element (code W, finer than the 40 um standard), a manual drain on the filter bowl, and a round gauge reading in psi on the regulator. The polycarbonate bowls let you see condensate and oil level at a glance, and the lubricator feeds an oil mist downstream to keep air tools and cylinders running smoothly.
This is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, and options including 40 um or 5 um filtration, differential-pressure, automatic or manual drains, and gauges scaled in MPa, psi or bar. Flow figures for this series are published as curves rather than a single rating, so ask us and we will confirm the datasheet numbers for your application before you order.
| Model | GC20006MC2W AirTAC F.R.L. Combination, PT1/8 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/8" · 5 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-06 |
| Build order | Filter → regulator → lubricator |
Feeding a small machining or assembly cell where air-driven tools need clean, regulated, lubricated supply - the 5 um element protects fine components and the lubricator keeps air tools oiled through the shift.
Supplying the air cylinders on a packaging or cartoning conveyor line: the regulator holds a steady working pressure for consistent cylinder stroke behaviour, while the filter removes water that would otherwise gum the valves.
Conditioning air ahead of spray guns or small finishing equipment, where the 5 um filtration and steady regulated pressure support a cleaner, more consistent finish and the lubricator is set to feed only downstream tools that need it.
Start with the port and size step: size 200 with PT1/8 ports suits compact circuits, while sizes 300, 400 and 600 step up in port and flow capacity - match the step to the air demand of the downstream equipment. This unit carries the 5 um element (W); choose it when finer particulate removal matters, or the 40 um standard element for general-purpose supply. The manual drain (M) means someone must bleed the filter bowl periodically - pick automatic or differential-pressure drain codes if the installation is unattended.
The round gauge on this unit reads in psi (scale 2); square embedded gauges and MPa or bar scales are also available in the family. PT thread is the standard here, with G (BSPP) and NPT available as order options. Flow for the GC series is published as curves, not a single rated figure, so send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.
AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote a rated flow number. Send us your application details and we will confirm the datasheet flow curves and help you check whether the size 200, PT1/8 configuration suits your air demand before you order.
The M in the code GC20006MC2W specifies a manual drain on the filter bowl: condensate collects in the polycarbonate bowl and someone opens the drain to release it. If the installation runs unattended, the GC family also offers automatic and differential-pressure drain codes that remove the need for manual bleeding - ask us about those variants.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.