The AirTAC GC20006MLF2WGK AirTAC F.R.L. Combination Unit, G1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one prepared air-supply set for compressed air. This GC200 unit is built for a G1/8 port on the size-200 body. It carries the W-grade 5 um filter element (40 um is the standard alternative), a manual drain on the filter bowl, a low-pressure regulator, an embedded square gauge scaled in psi, and a reverse/check valve. The polycarbonate bowl suits the 200 size, the mounting bracket is included, and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GC series spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and options for thread type (PT standard; G or NPT to order), drain type, filter grade, gauge scale and reverse/check valve. Rated flow is published as curves rather than a single figure, so ask us to confirm the datasheet and sizing for your application.
| Model | GC20006MLF2WGK AirTAC F.R.L. Combination Unit, G1/8 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/8" (G (BSPP) thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/8" · 5 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-06 |
| Build order | Filter → regulator → lubricator |
Feeds filtered, regulated and lubricated air to small pneumatic clamps on an assembly bench, holding the set pressure steady through repeat clamping cycles.
Supplies treated air to small gripper and slide cylinders on electronics or small-parts assembly modules where the circuit runs at a low set pressure.
Conditions the air feed to bench-top test rigs and laboratory pneumatic circuits, with 5 um filtration and oil mist for the valves and cylinders downstream.
Every choice in this series is decodable from the code. Step through sizes 200/300/400/600 and ports 1/8 to 1 inch to match the flow your line needs - we confirm the flow curves against your demand before you order. Choose the drain: manual (this unit, code M) is emptied by hand at intervals, while automatic and differential-pressure drains discharge without attention. Choose the filter grade: 40 um standard or 5 um (W, this unit). Gauges are embedded square as standard with MPa, psi or bar scales, and an external round gauge is optional. Thread is PT as standard with G and NPT as order options; the bracket is included. Max inlet pressure is 1.0 MPa (145 psi). This is the low-pressure (L) regulator version for circuits set below the standard range; its exact range is not published, so confirm it with us alongside your set pressure.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number here. Send us your line demand and we will confirm the sizing from the datasheet before you order.
Code M fits a manual drain on the filter bowl: open it at intervals to expel collected water, or order the automatic or differential-pressure drain version if you want the bowl to discharge without attention. This unit also carries the 5 um (W) element instead of the standard 40 um.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.