verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC20008LC2 AirTAC F.R.L. Combination Unit, PT1/4

The AirTAC GC20008LC2 AirTAC F.R.L. Combination Unit, PT1/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$60.13 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC20008LC2 AirTAC F.R.L. Combination Unit, PT1/4

The GC20008LC2 is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one air-preparation set. This size 200 configuration has PT1/4 (1/4 in) ports, a 40 um filter element, a differential-pressure drain on the filter bowl, a low-pressure type regulator, and a round pressure gauge with a psi scale. The polycarbonate bowls suit standard duty, a mounting bracket is included, and the set handles compressed air at up to 1.0 MPa (145 psi) inlet with an operating temperature of -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600, with port options from 1/8 in to 1 in, G (BSPP) or NPT threads to order, 5 um filtration as an option, automatic or manual drains, gauge scale choices and bracket variations. Flow is published as curves rather than a single rated figure, so we confirm flow and datasheet figures on request before you order.

GC20008LC2 AirTAC F.R.L. Combination Unit, PT1/4 Technical Specifications

ModelGC20008LC2 AirTAC F.R.L. Combination Unit, PT1/4
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC20008LC2 AirTAC F.R.L. Combination Unit, PT1/4

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 40 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the GC20008LC2 AirTAC F.R.L. Combination Unit, PT1/4 Is Used

precision_manufacturing

Assembly-line pneumatic tool supply

Feeds filtered, regulated and lubricated air to impact drivers, nut runners and riveters on a bench or cell assembly line, keeping tools lubricated and set pressure stable across a shared 1/4 in drop.

conveyor_belt

Packaging machine actuator air prep

Conditions the air feeding cylinders and grippers on a cartoning or case-packing conveyor, removing water and particulate ahead of valves while holding a low set pressure for gentle product handling.

factory

Workshop drop-leg air conditioning

Installed at a point-of-use drop on a plant compressed-air ring main, giving a work station clean, regulated and oil-misted air for clamps, air tables and small actuators without a separate filter set.

Is the GC20008LC2 AirTAC F.R.L. Combination Unit, PT1/4 the Right Station?

Size 200 with PT1/4 ports is the entry step of the GC range; step up to 300, 400 or 600 when the application needs larger ports and more flow. Choose the drain type for the filter bowl: differential-pressure (as fitted here) drains on pressure drop, automatic drains hands-free, and manual drains on demand. The 40 um element is the standard grade; specify 5 um (code W) where finer particulate removal matters. This unit is the low-pressure regulator type, suited to circuits that work at reduced set pressures - confirm the exact adjustment range with us before ordering. The round gauge reads in psi; MPa and bar scales are also available. Thread is PT as standard, with G (BSPP) and NPT as orderable options, and the mounting bracket is included.

Because flow is published as curves and not a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

GC20008LC2 AirTAC F.R.L. Combination Unit, PT1/4 FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote one number. Tell us your inlet pressure and the flow your application needs, and we will confirm the correct size against the datasheet curves on request before you order.

The L in GC20008LC2 marks the low-pressure type regulator, intended for circuits that operate at reduced set pressures rather than full line pressure. The exact adjustment range for the low-pressure type is not published in the standard sheet, so confirm your required set pressure with us and we will verify suitability on request. The round gauge fitted here reads in psi; MPa or bar scales can be ordered instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC20008LC2 AirTAC F.R.L. Combination Unit, PT1/4

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC20008LC2 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.