The AirTAC GC20008MC2GK AirTAC F.R.L. Combination, G1/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one supply unit. This GC20008MC2GK is the 200 size with G1/4 ports, a 40 um filter element and a manual drain, so the bowl is emptied by hand as part of routine checks. The regulator is the standard type with a 0.05-0.9 MPa (7-130 psi) adjustment range, the set carries a round gauge reading in psi, and a reverse/check valve is fitted. The polycarbonate bowls and mounting bracket suit the -5 to 70 C non-freezing operating range at up to 1.0 MPa (145 psi) inlet.
This is a genuine AirTAC part. The GC family spans the 200, 300, 400 and 600 sizes with port options from 1/8 to 1 inch, plus choices for drain type, 40 um or 5 um filtration, gauge scale and PT, G or NPT thread. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet and sizing figures for your application before ordering.
| Model | GC20008MC2GK AirTAC F.R.L. Combination, G1/4 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (G (BSPP) thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/4" · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-08 |
| Build order | Filter → regulator → lubricator |
Point-of-use air preparation for impact wrenches, air ratchets and clamping fixtures at car-plant assembly stations, where one unit filters, regulates and oils the supply.
Clean, regulated, lubricated air for the cylinders and grippers that run carton-forming and case-packing conveyors in a beverage bottling plant.
Feeding lifts, impact guns and tire changers in a commercial-vehicle workshop, with the manual drain emptied during end-of-day checks.
Choose the size by port and required flow: 200 covers G1/4 here, while 300, 400 and 600 step up to larger ports and higher flow. Drain is a real choice: manual (this model) needs periodic hand draining, automatic handles condensate by itself, and differential-pressure drains on pressure drop. Filtration is 40 um standard or 5 um (code W) for finer protection. The gauge can read MPa, psi or bar, and thread can be ordered as PT (standard), G or NPT. Flow is published as curves, not a single rated figure, so send us your application and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a number here. Tell us your working pressure and air demand and we will confirm the flow from the datasheet for this G1/4 three-unit set before you order.
The M in GC20008MC2GK specifies a manual drain: condensate collected in the filter bowl is released by hand, which suits lines checked on a fixed schedule. Automatic and differential-pressure drain options are available in the same GC200 series if you prefer unattended drainage.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.