The AirTAC GC200C06MLF2WG AirTAC F.R.L. Combination, G1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator assembled as one air-preparation set. This configuration, GC200C06MLF2WG, is the size 200 unit with a 1/8 in port in G (BSPP) thread. The filter stage carries the fine 5 um element (code W) with a manual drain, so an operator opens the drain at the bowl to expel collected water. The regulator is the low-pressure type and is fitted with an embedded square gauge scaled in psi; the lubricator mists oil into the downstream air. A mounting bracket is included, and no reverse (check) valve is fitted.
This is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in up to 1 in, and options that include drain type, filter grade, gauge scale (MPa, psi or bar), thread (PT standard, G or NPT to order) and a reverse valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the flow and datasheet figures for this exact model against your application before ordering.
| Model | GC200C06MLF2WG AirTAC F.R.L. Combination, G1/8 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Feeding a compact air press or clamping fixture where the cylinder supply needs filtered, regulated and lightly oiled air at a low set pressure, with the psi gauge giving the operator a direct readout at the station.
Air preparation for the diverters, pushers and sealing heads on a packaging conveyor, where the 5 um element protects the small control valves from water and particulate carryover.
Point-of-use preparation on textile or knitting machinery that runs on low-pressure air circuits, combining filtration, low-pressure regulation and lubrication in one bracket-mounted set at the machine.
Start with the port: size 200 in this code gives a 1/8 in port, the smallest step in the GC range, so step up to 300/400/600 if your line needs more flow capacity. Choose the drain to match maintenance habits: this model has a manual drain, which suits attended installations; automatic or differential-pressure drains suit unattended duty. The 5 um element (code W) is the finer choice over the 40 um standard where downstream valves and cylinders need cleaner air. The regulator here is the low-pressure type; its adjustment range is not published for this code, so confirm it with us. Gauge scale is psi on the embedded square gauge, with MPa or bar scales and an external round gauge available as options. Thread is G (BSPP) here; PT is the standard thread and NPT is orderable. A bracket is included.
One honest note on sizing: flow for this series is published as curves, not a single rated number, so send us your application details and we will confirm the correct size from the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as characteristic curves, not as a single rated figure, so we do not quote a number here. Tell us your working pressure and the air demand of the equipment downstream, and we will confirm the flow from the datasheet for this exact model before you order.
The M in the code GC200C06MLF2WG specifies a manual drain on the filter bowl: an operator opens it to discharge collected water, which suits installations that are checked regularly. If the unit will run unattended, ask us about the same GC200 size with an automatic or differential-pressure drain instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.