The AirTAC GC200C08MC2K AirTAC F.R.L. Combination, PT1/4, Manual Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$84.25 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC200C08MC2K AirTAC F.R.L. Combination, PT1/4, Manual Drain

The GC200C08MC2K is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one set. This configuration is sized for 1/4 in PT ports and carries a 40 um filter element with a manual drain on the filter bowl, a standard regulator with an external round psi gauge for setting downstream pressure, and a built-in reverse/check valve that holds downstream settings when upstream supply is lost. The polycarbonate bowl and included mounting bracket make it a straightforward point-of-use treatment station.

This is a genuine AirTAC part from the GC200 series, one of four sizes (200/300/400/600) covering larger ports and higher flow capacity as the number rises. Options across the series include automatic or differential-pressure drains, a 5 um filter element, alternative gauge scales (MPa/psi/bar) and G or NPT threads. We confirm flow and datasheet figures on request, since AirTAC publishes flow as curves rather than a single rating.

GC200C08MC2K AirTAC F.R.L. Combination, PT1/4, Manual Drain Technical Specifications

ModelGC200C08MC2K AirTAC F.R.L. Combination, PT1/4, Manual Drain
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC200C08MC2K AirTAC F.R.L. Combination, PT1/4, Manual Drain

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the GC200C08MC2K AirTAC F.R.L. Combination, PT1/4, Manual Drain Is Used

factory

Automotive assembly workstation

A point-of-use F.R.L. station feeding impact wrenches, nutrunners and air cylinders at an assembly cell: the filter strips water and swarf from the shop-air drop, the regulator holds a steady setting for consistent tool torque, and the lubricator mists oil to extend tool life.

conveyor_belt

Packaging line pneumatic pushers

Treating the air supply to diverters, pushers and clamp cylinders on a packaging conveyor. The check valve holds the regulated downstream pressure through brief supply dips so product-handling strokes stay repeatable, while the manual drain suits a shift-start maintenance check.

precision_manufacturing

Pneumatic press and clamping cell

Supplying a bench pneumatic press or clamping fixture where clean, regulated and lubricated air protects seals and cylinders. The round psi gauge lets the operator set and verify clamping pressure directly, and the 40 um element guards valve spools from particulate carried in from the plant ring main.

Is the GC200C08MC2K AirTAC F.R.L. Combination, PT1/4, Manual Drain the Right Station?

Start with the port and size: this unit is the 200 size with a 1/4 in PT port; step up to 300/400/600 when the application needs a larger port and more flow. Choose the drain to match maintenance routines - manual drain (as here) means an operator opens the bowl drain, while automatic or differential-pressure drains discharge condensate without hands-on attention. Filter grade is 40 um as standard; specify the W option for 5 um where finer particulate removal matters. The gauge here reads in psi; MPa and bar scales are also available, and an embedded square gauge is the standard alternative to this external round gauge. Thread is PT as standard, with G (BSPP) and NPT as order options, and a bracket is included. Because AirTAC publishes flow only as curves rather than a single rated figure, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

GC200C08MC2K AirTAC F.R.L. Combination, PT1/4, Manual Drain FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a rated flow number, Cv or SCFM. Tell us your application and we will confirm the relevant flow and datasheet figures on request before you order.

The M in the code specifies a manual drain on the filter bowl: an operator opens the drain to discharge collected condensate, which suits stations checked on a regular maintenance round. If you prefer hands-off condensate removal, the GC series is also available with an automatic (A) or differential-pressure (blank) drain - just ask for the equivalent model code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC200C08MC2K AirTAC F.R.L. Combination, PT1/4, Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C08MC2K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.