verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC200C08MF2K AirTAC F.R.L. Combination, PT1/4

The AirTAC GC200C08MF2K AirTAC F.R.L. Combination, PT1/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$84.26 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC200C08MF2K AirTAC F.R.L. Combination, PT1/4

The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one supply unit. This GC200C08MF2K is the 200 size with PT1/4 ports, a manual drain on the filter bowl, the standard 40 um filter element, an embedded square gauge reading in psi, a reverse/check valve fitted and the mounting bracket included. The polycarbonate bowls suit the -5 to 70 C (non-freezing) operating range, the maximum inlet pressure is 1.0 MPa (145 psi), and the regulator adjusts from 0.05-0.9 MPa (7-130 psi).

This is a genuine AirTAC part. The GC family is available in 200, 300, 400 and 600 sizes covering ports from 1/8 in to 1 in, with manual, automatic or differential-pressure drains, a 5 um element option (code W), gauge scales in MPa, psi or bar, and G or NPT threads as catalogue options to order. Flow is published as curves rather than a single rating, so ask us to confirm sizing and datasheet figures for your application.

GC200C08MF2K AirTAC F.R.L. Combination, PT1/4 Technical Specifications

ModelGC200C08MF2K AirTAC F.R.L. Combination, PT1/4
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC200C08MF2K AirTAC F.R.L. Combination, PT1/4

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the GC200C08MF2K AirTAC F.R.L. Combination, PT1/4 Is Used

precision_manufacturing

CNC machine shop workholding

Feeding pneumatic clamps and vise actuators on a CNC cell: the filter removes water and particulate, the regulator holds a steady clamp pressure, and the lubricator mists oil to the valve and cylinder seals.

conveyor_belt

Bottling line conveyor controls

Mounted at the air drop feeding a bottling plant's conveyor stopper and diverting cylinders, so each shift starts with dry, regulated and lubricated air instead of a wet, unregulated supply.

factory

Automotive assembly air tools

Supplying impact wrenches and pneumatic screwdrivers at an automotive assembly station, where the 40 um element protects the tools and the lubricator keeps the vane motors running through a full shift.

Is the GC200C08MF2K AirTAC F.R.L. Combination, PT1/4 the Right Station?

Step through the 200/300/400/600 sizes to match the port and flow your line needs; this unit sits at the 200 size on PT1/4. Choose the drain to suit your maintenance routine: manual (as here) means someone opens the drain at set intervals, automatic drains without attention, and the default differential-pressure drain bleeds as the pressure differential builds. Filter grade is 40 um standard or 5 um with the W code; the square gauge can be ordered in MPa, psi or bar scales; PT is the standard thread with G and NPT as order options; and the bracket is included. Because flow is published as curves rather than a single rated figure, send us your application and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

GC200C08MF2K AirTAC F.R.L. Combination, PT1/4 FAQ

Flow for the GC series is published as curves rather than a single rated figure, so we do not quote a number on the page. Tell us your working pressure and the air demand of the equipment you are feeding, and we will confirm the sizing from the AirTAC datasheet on request.

The M code selects a manual drain: the filter bowl is drained by hand at intervals you set during maintenance. If you would rather not rely on someone opening the drain, the same GC200-08 combination can be ordered with an automatic drain (code A) or the default differential-pressure drain.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC200C08MF2K AirTAC F.R.L. Combination, PT1/4

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C08MF2K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.