verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC200C08MLF2WGK AirTAC F.R.L. Combo G1/4 5um Manual Drain

The AirTAC GC200C08MLF2WGK AirTAC F.R.L. Combo G1/4 5um Manual Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$83.93 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC200C08MLF2WGK AirTAC F.R.L. Combo G1/4 5um Manual Drain

The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one air-preparation set. This GC200C08MLF2WGK is the 200 size with G1/4 (BSPP) ports. The filter stage carries the 5 um element (code W) with a manual drain on its metal bowl, so an operator drains accumulated water rather than relying on an automatic or differential-pressure drain. The regulator is the low-pressure type (code L) for circuits that are set below standard regulator ranges, and it is fitted with the embedded square gauge scaled in psi. A reverse/check valve (code K) is fitted, and the mounting bracket is included. Together the three stages deliver filtered, regulated and lubricated compressed air to downstream cylinders, valves and air tools.

This is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600 with matching port sizes, and options include differential-pressure, automatic or manual drains, 40 um or 5 um filter elements, square or external round gauges scaled in MPa, psi or bar, and PT, G or NPT threads. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and datasheet figures for your application before ordering.

GC200C08MLF2WGK AirTAC F.R.L. Combo G1/4 5um Manual Drain Technical Specifications

ModelGC200C08MLF2WGK AirTAC F.R.L. Combo G1/4 5um Manual Drain
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC200C08MLF2WGK AirTAC F.R.L. Combo G1/4 5um Manual Drain

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the GC200C08MLF2WGK AirTAC F.R.L. Combo G1/4 5um Manual Drain Is Used

factory

Automotive assembly station air supply

Feeding filtered, regulated and lubricated air to impact wrenches, pneumatic screwdrivers and air ratchets at a vehicle assembly station, with the 5 um element protecting tools from water and fine particulate and the lubricator oil-misting the air for tool life.

precision_manufacturing

CNC machine shop pneumatic circuits

Preparing air for pneumatic clamps, tool-change actuators and chip-blow-off nozzles on a CNC machining centre, where the low-pressure regulator holds a reduced set point and the check valve helps hold downstream pressure.

conveyor_belt

Packaging line carton-sealing equipment

Supplying conditioned air to case erectors, tape heads and box-flap cylinders on a packaging conveyor line, with manual bowl draining during shift checks and the psi gauge giving operators a local pressure readout.

Is the GC200C08MLF2WGK AirTAC F.R.L. Combo G1/4 5um Manual Drain the Right Station?

Start with the size and port: the 200 body here takes a 1/4 in port, and stepping up to 300, 400 or 600 buys larger ports and more flow capacity, so match the size to the air demand of the circuit rather than to the pipe alone. Next choose the drain: this unit has a manual drain, which suits attended installations where an operator can bleed the filter bowl; choose automatic or differential-pressure drain codes where the unit is inaccessible or you want draining without intervention. The filter grade here is the 5 um element (code W); the 40 um standard element is the usual choice for general shop air, while 5 um suits finer downstream equipment. The gauge is the embedded square type scaled in psi; MPa or bar scales and an external round gauge are alternatives. Thread: PT is the standard, with G (BSPP) and NPT as catalogue options to order - this unit is the G-thread version. A mounting bracket is included, and the reverse/check valve is fitted. For sizing, flow is published as curves, not a single rating, so ask us to confirm the selection against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

GC200C08MLF2WGK AirTAC F.R.L. Combo G1/4 5um Manual Drain FAQ

AirTAC publishes flow for the GC series as performance curves, not as a single rated figure, so we do not quote one number. Tell us your application and required consumption and we will confirm the flow from the datasheet curves for this 200 size, G1/4 unit on request before you order.

The L in the code marks the low-pressure version of the regulator, intended for circuits that are set below the standard regulator range. The exact adjustment range for the low-pressure type is not published in the data we hold, so ask us to confirm it on request. The rest of the decode is standard: manual drain, 5 um filter element, square psi gauge, check valve fitted, bracket included.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC200C08MLF2WGK AirTAC F.R.L. Combo G1/4 5um Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C08MLF2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.