verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30008MLF2WG AirTAC F.R.L. Combination, G1/4

The AirTAC GC30008MLF2WG AirTAC F.R.L. Combination, G1/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$87.07 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30008MLF2WG AirTAC F.R.L. Combination, G1/4

The AirTAC GC30008MLF2WG is a three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one GC300 set. It conditions compressed air in a single installation point, removing water and particulate down to 5 um (the W fine-grade element), holding a set downstream pressure with the low-pressure type regulator, and adding oil mist for downstream air tools and cylinders. This configuration is built with a G1/4 (BSPP) port, a manual drain on the filter bowl, an embedded square gauge reading in psi, and no reverse/check valve fitted. The polycarbonate bowls suit the -5 to 70 C non-freezing operating range, with a maximum inlet pressure of 1.0 MPa (145 psi), and a mounting bracket is included.

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600, with port sizes from 1/8 in to 1 in, PT (standard), G or NPT threads, differential-pressure, automatic or manual drains, 40 um standard or 5 um fine filtration, standard or low-pressure regulators, and MPa, psi or bar gauge scales. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.

GC30008MLF2WG AirTAC F.R.L. Combination, G1/4 Technical Specifications

ModelGC30008MLF2WG AirTAC F.R.L. Combination, G1/4
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30008MLF2WG AirTAC F.R.L. Combination, G1/4

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the GC30008MLF2WG AirTAC F.R.L. Combination, G1/4 Is Used

precision_manufacturing

Pneumatic press and clamping fixtures

A stamping or assembly shop running air cylinders on clamping and press fixtures installs this F.R.L. at the drop: the 5 um element keeps water and scale out of the valve stack, the low-pressure regulator holds a gentle clamping force, and the lubricator mists oil to the cylinders.

conveyor_belt

Packaging line actuator supply

On a packaging or bottling line with pick-and-place and box-forming actuators, this three-unit set at the line inlet filters condensate and dust, regulates the supply to the actuator circuit, and feeds oil mist to keep the air cylinders sealing smoothly through long production runs.

tune

Low-pressure test and process rigs

A leak-test or process rig that runs its pneumatic section at reduced pressure uses the low-pressure type regulator in this GC300 set to hold a stable, low setpoint, while the 5 um filter protects sensitive gauges and the lubricator conditions any air-driven tooling on the bench.

Is the GC30008MLF2WG AirTAC F.R.L. Combination, G1/4 the Right Station?

Start with the port step: this GC300 set takes a G1/4 (BSPP) connection; if your circuit needs a larger bore, step up to GC400 or GC600, and down to GC200 for smaller lines. Because flow is published as curves and not a single rated number, let us check the curve for your size against your air demand before you order. On filtration, 40 um is the standard element and the W code on this unit specifies the finer 5 um grade - choose it where downstream valves and cylinders need cleaner air. The manual drain on the filter bowl means an operator or maintenance round opens the drain; if you cannot schedule that, ask about automatic or differential-pressure drain versions. The regulator on this unit is the low-pressure type, intended for circuits set below the standard range; its exact adjustment range is not published, so confirm it with us against your setpoint. The fitted square gauge reads in psi; MPa and bar scales and an external round gauge are alternatives. PT is the standard thread, with G (this unit) and NPT as catalogue options, and brackets are included.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

GC30008MLF2WG AirTAC F.R.L. Combination, G1/4 FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a rated flow number. Tell us your line pressure and air demand and we will confirm the sizing from the datasheet curves for the GC300 size and G1/4 port before you order.

The M code in GC30008MLF2WG specifies a manual drain on the filter bowl: accumulated water must be drained by hand as part of a maintenance round. If your installation cannot rely on scheduled draining, GC sets are also available with automatic or differential-pressure drains - ask us for those variants.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30008MLF2WG AirTAC F.R.L. Combination, G1/4

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30008MLF2WG and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.