The AirTAC GC400-10 AirTAC F.R.L. Combination, PT3/8, 5 um Filter is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC400-10 is a genuine AirTAC three-piece F.R.L. combination: separate filter, regulator and lubricator units assembled as one air-preparation set. This configuration is built for 3/8 in PT ports, carries the 5 um filter element (the finer of the two published grades), an automatic drain on the polycarbonate filter bowl, and a round pressure gauge reading in psi. A reverse/check valve is fitted and the set includes a mounting bracket. In use it prepares compressed air in three steps: it strips water and particulate down to 5 um, holds downstream pressure steady anywhere in the 0.15-0.9 MPa (20-130 psi) adjustment range, and meters a fine oil mist to lubricate downstream cylinders, valves and air tools.
This is a genuine AirTAC part in the GC series, which spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, a choice of PT, G or NPT thread, manual, automatic or differential-pressure draining, 40 um or 5 um filtration, and gauge scales in MPa, psi or bar. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). Rated flow is published as curves rather than a single figure, so ask us to confirm flow and datasheet details for your application before ordering.
| Model | GC400-10 AirTAC F.R.L. Combination, PT3/8, 5 um Filter |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT3/8" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · PT3/8" · 5 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-10 |
| Build order | Filter → regulator → lubricator |
Spray guns and air-assisted applicators need air that is dry, filtered, held at a set pressure and lightly oiled. This combination conditions the drop line feeding a paint booth: the 5 um element removes fine particulate before it can blemish a finish, the regulator holds gun pressure steady, and the lubricator keeps gun triggers and spindles working smoothly.
Pneumatic clamps, tool-change cylinders and chip-clearing blasts on a machining centre all draw from one prep point. This F.R.L. set at the cell inlet cleans the shop air to 5 um, locks clamp pressure against shop-line fluctuation, and oils the actuators, while the automatic drain handles condensate without an operator stopping by.
High-cycle pick-and-place cylinders, grippers and diverters on a packaging line wear fast on unconditioned air. Feeding the machine's valve stack through this combination gives filtered, moisture-managed air at a stable set pressure with continuous oil-mist lubrication, and the check valve holds the circuit if the supply side dips.
Size and port: the 400 size with 3/8 in PT ports sits mid-range in the GC series; step up or down (200/300/400/600, 1/8 in to 1 in) according to the air demand of the circuit - flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering. Drain: this unit has the automatic drain, which bleeds collected condensate without manual attention; manual and differential-pressure drain versions exist in the family. Filter grade: the 5 um element (code W) is fitted here instead of the standard 40 um, the right choice where finer particulate removal matters. Gauge: this build carries the external round gauge with a psi scale; embedded square gauges and MPa or bar scales are the other catalogue options. Thread: PT is the standard; G (BSPP) and NPT are order options. A mounting bracket is included and a reverse/check valve is fitted.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated number, so we do not quote a fixed l/min or SCFM figure. Tell us your application and we will confirm the flow and full datasheet details for this model on request before you order.
The W in the code GC40010AC2WK selects the 5 um element instead of the 40 um standard, and the A selects the automatic drain, which ejects collected condensate on its own instead of waiting for a manual or differential-pressure drain cycle. Both are catalogue options on the GC filter stage, so you can order the family with 40 um filtration or a different drain if that suits the installation better.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.