AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC400C10C2GK AirTAC F.R.L. Combination, G3/8

The AirTAC GC400C10C2GK AirTAC F.R.L. Combination, G3/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$149.10 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC400C10C2GK AirTAC F.R.L. Combination, G3/8

The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled into one conditioning station. This GC400C10C2GK is built on the 400 size with a G3/8 (BSPP) port. The filter section carries the standard 40 um element with a differential-pressure drain, the standard-type regulator adjusts from 0.15-0.9 MPa (20-130 psi), and the lubricator feeds oil mist to downstream equipment. A round gauge scaled in psi is fitted, a reverse/check valve is included, and the set is supplied with a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing; on this 400 size the bowls are polycarbonate (PC).

This is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and options include manual or automatic drains, a 5 um filter element (code W), gauges scaled in MPa, psi or bar, and G or NPT threads in place of the PT standard. Flow is published as curves rather than a single rating, so ask us to confirm the sizing figures from the datasheet for your application.

GC400C10C2GK AirTAC F.R.L. Combination, G3/8 Technical Specifications

ModelGC400C10C2GK AirTAC F.R.L. Combination, G3/8
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC400C10C2GK AirTAC F.R.L. Combination, G3/8

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the GC400C10C2GK AirTAC F.R.L. Combination, G3/8 Is Used

precision_manufacturing

CNC machine clamping circuits

Filtered, regulated and lubricated air for pneumatic clamps and vises on machining centres, where clean air and a stable set pressure protect both the workpiece and the tooling.

conveyor_belt

Packaging line actuators

A single conditioning point feeding cylinders and grippers on bottling and cartoning conveyors, with the lubricator keeping seals moving smoothly through long production runs.

factory

Assembly line air tools

Conditioned air for impact drivers, nut runners and air ratchets at assembly stations, with the fitted round psi gauge letting operators verify the set pressure at a glance.

Is the GC400C10C2GK AirTAC F.R.L. Combination, G3/8 the Right Station?

Choose the size by port and flow: the series steps from 200 up to 600, covering 1/8 in to 1 in ports, and this 400 size gives a 3/8 in G thread. Drain options are differential-pressure (this unit), automatic (code A) or manual (code M). The filter grade is 40 um standard; specify W for 5 um. Gauges can be ordered with MPa, psi or bar scales - this unit carries a round psi gauge - and the embedded square gauge is the standard alternative. Thread is G (BSPP) here; PT is the standard and NPT is an order option. A mounting bracket is included. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

GC400C10C2GK AirTAC F.R.L. Combination, G3/8 FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the flow figures from the datasheet on request before you order.

C2 specifies the fitted round gauge scaled in psi, with MPa and bar scales available as alternatives, and K means a reverse/check valve is fitted. This unit also carries the standard 40 um filter element and a differential-pressure drain; 5 um (W), automatic (A) and manual (M) versions can be ordered.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC400C10C2GK AirTAC F.R.L. Combination, G3/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C10C2GK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.