The AirTAC GC400C10F2 AirTAC F.R.L. Combination Unit, PT3/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC400C10F2 is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one set for compressed-air preparation. This configuration is the 400 size with a 3/8 in PT port. The filter element is the standard 40 um grade with a differential-pressure drain, the regulator is the standard type with a square gauge scaled in psi, and a mounting bracket is included.
This is a genuine AirTAC part. The GC family is published in sizes 200, 300, 400 and 600, with port options, drain types, filter grades, gauge scales and thread variants to match the line. Flow figures are published as curves rather than a single rating, so we confirm the datasheet figures for your application on request.
| Model | GC400C10F2 AirTAC F.R.L. Combination Unit, PT3/8 |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · See datasheet · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-C1 |
| Build order | Filter → regulator → lubricator |
Feeding spray guns and air-assisted applicators at a paint line, where the filter removes water and particulate, the regulator holds a steady setting and the lubricator mists oil to the air motor.
Supplying the cylinders and grippers on a carton-sealing conveyor, giving the machine one point where air is cleaned, pressure is set and moving seals receive oil mist.
Preparing the air to pneumatic clamps and tool-change actuators on a machining centre, with the regulator holding the clamp pressure and the lubricator protecting the cylinder seals and moving parts.
Choose the GC size and port step against the air demand of the line: 200, 300, 400 and 600 step up in port size and flow capacity, and this unit sits at the 400 size with a 3/8 in PT port. Where a bowl is fitted, pick the drain type - differential-pressure (as here), automatic, or manual - and the filter grade, 40 um standard or 5 um with code W. Select the gauge scale (MPa, psi or bar) and the thread: PT is the standard, with G (BSPP) and NPT available as order options.
Because flow is published as curves rather than a single rated figure, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.
AirTAC publishes flow for this family as curves, not as a single rated figure, so we do not quote a number. Send us your line demand and we will confirm the flow figures from the datasheet for this 400-size, 3/8 in PT unit on request.
A GC set is a separate filter, regulator and lubricator - three pieces - while a GFC combines the filter and regulator in one body and adds a separate lubricator. The GC layout gives you individual access to each function; this unit is the three-piece combination at 400 size with a 40 um element, differential-pressure drain and a square psi gauge.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.