verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC400C10LC2WK AirTAC F.R.L. Combination, PT3/8, 5 um

The AirTAC GC400C10LC2WK AirTAC F.R.L. Combination, PT3/8, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$149.76 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC400C10LC2WK AirTAC F.R.L. Combination, PT3/8, 5 um

The AirTAC GC400C10LC2WK is a three-piece F.R.L. combination for 3/8 in (PT3/8) compressed-air lines: a filter, a pressure regulator and an oil-mist lubricator, each in its own body and assembled as one air-preparation set. This configuration carries the W filter element (5 um, finer than the 40 um standard element), a differential-pressure drain on the filter bowl, a low-pressure-type regulator fitted with an external round gauge scaled in psi, and a reverse/check valve. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing); the filter bowl on this 400 size is PC (polycarbonate), and a mounting bracket is included.

This is a genuine AirTAC part. The GC family is offered in sizes 200, 300, 400 and 600, with a choice of port sizes, PT (standard), G or NPT threads, 40 um or 5 um filtration, manual, automatic or differential-pressure drains, standard or low-pressure regulators, and gauge scale options. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet and sizing figures for your application on request.

GC400C10LC2WK AirTAC F.R.L. Combination, PT3/8, 5 um Technical Specifications

ModelGC400C10LC2WK AirTAC F.R.L. Combination, PT3/8, 5 um
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC400C10LC2WK AirTAC F.R.L. Combination, PT3/8, 5 um

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the GC400C10LC2WK AirTAC F.R.L. Combination, PT3/8, 5 um Is Used

factory

Low-pressure pneumatic circuit on a packaging line

Feeds clean, regulated, lubricated air to carton-forming and sealing cylinders that run at reduced setpoints, with the low-pressure regulator and 5 um element protecting the actuators and valve islands.

settings_input_component

Valve-stand supply on an assembly automation cell

A single PT3/8 preparation point ahead of a directional-valve manifold: water and 5 um particulate removal, pressure regulation with a psi gauge for setting, and oil mist for cylinder life.

handyman

Central air-tool drop in a maintenance workshop

Serves impact wrenches, nutrunners and air ratchets from a 3/8 in drop, combining fine filtration, a low-pressure regulated supply read on the round psi gauge, and lubrication for the tool motors.

Is the GC400C10LC2WK AirTAC F.R.L. Combination, PT3/8, 5 um the Right Station?

Start with the port size: this unit is 3/8 in (PT3/8) on the 400 body; step up or down through sizes 200/300/400/600 if your line needs a different connection or flow path. Choose the filter grade - 40 um standard or the finer 5 um fitted here (code W) - and the drain: differential-pressure (default, as fitted), automatic (A) or manual (M). The regulator here is the low-pressure type (code L); its adjustment range is not published in the material we hold, so confirm it with us before ordering if your setpoint is critical. Gauge options are the embedded square gauge (MPa/psi/bar scales) or an external round gauge such as the psi unit fitted here. Threads come as PT (standard), G or NPT - order the suffix you need. Flow is published as curves, not a single rated figure, so send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

GC400C10LC2WK AirTAC F.R.L. Combination, PT3/8, 5 um FAQ

AirTAC publishes flow for this family as curves rather than a single rated figure, so we do not quote one number. Tell us your line pressure and the flow your application needs, and we will confirm the sizing against the datasheet on request before you order.

The L code marks the low-pressure regulator variant, and the exact adjustment range for it is not published in the material we hold, so we will not quote a figure. Ask us to confirm the range from the datasheet on request; the standard (non-L) GC regulator is also available if your setpoint sits in the conventional range.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC400C10LC2WK AirTAC F.R.L. Combination, PT3/8, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C10LC2WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.