The AirTAC GC400C10MC2G AirTAC F.R.L. Combination, G3/8, Manual Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$137.86 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC400C10MC2G AirTAC F.R.L. Combination, G3/8, Manual Drain

The GC400C10MC2G is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one filtered-air supply point. This configuration is built for 3/8 in lines with G (BSPP) threads, carries the size 400 body, and is set up with a manual drain on the filter bowl, the standard 40 um filter element, and a round pressure gauge reading in psi. The standard regulator covers an adjustment range of 0.05-0.9 MPa (7-130 psi), the unit accepts a maximum inlet pressure of 1.0 MPa (145 psi), and it operates in -5 to 70 C (non-freezing) compressed air. A mounting bracket is included.

This is a genuine AirTAC part. The GC family is offered across sizes 200, 300, 400 and 600, with choices of drain type, 40 um or 5 um (W) filtration, gauge style and scale, and PT, G or NPT threads. Because flow is published as curves rather than a single rating, we confirm the datasheet and sizing figures for your application on request.

GC400C10MC2G AirTAC F.R.L. Combination, G3/8, Manual Drain Technical Specifications

ModelGC400C10MC2G AirTAC F.R.L. Combination, G3/8, Manual Drain
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC400C10MC2G AirTAC F.R.L. Combination, G3/8, Manual Drain

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the GC400C10MC2G AirTAC F.R.L. Combination, G3/8, Manual Drain Is Used

factory

Automotive paint-shop air drops

A filtered, regulated and lubricated supply point at each spray-booth drop, where clean, pressure-set and oil-misted air feeds the spray guns and air motors on the line.

conveyor_belt

Carton-sealing conveyor cylinders

One F.R.L. set feeding the extend-and-press cylinders and grippers on a packaging conveyor, keeping the actuator air clean, held at set pressure and lubricated through the shift.

build

Machine-shop pneumatic workholding

Air preparation for clamps and vise cylinders on a CNC machining cell, where the operator sets regulated pressure at the gauge and the lubricator mists the clamp actuators.

Is the GC400C10MC2G AirTAC F.R.L. Combination, G3/8, Manual Drain the Right Station?

Start with the port step: size 400 on this model gives a 3/8 in connection, so step up or down through the 200/300/400/600 range if your line or expected air demand calls for a different port. The filter grade here is the standard 40 um element; choose the W option for 5 um filtration where downstream equipment needs finer particle removal. Drain type is a real decision: this unit has a manual drain, which means someone drains the bowl on a routine, while automatic or differential-pressure drains suit points that are hard to reach. The round gauge on this configuration reads in psi; square embedded gauges and MPa or bar scales are the other catalogue choices. Thread is G (BSPP) here, with PT as the standard thread and G/NPT as order options, and the bracket is included. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

GC400C10MC2G AirTAC F.R.L. Combination, G3/8, Manual Drain FAQ

AirTAC publishes flow for this family as curves, not as a single rated figure, so there is no one number we can quote. Send us your line pressure and air demand and we will confirm the sizing from the datasheet on request.

The M in the code sets the filter bowl drain to manual: collected water is released by hand on a routine. It suits accessible mounting points with a maintenance walk, while automatic or differential-pressure drains are the catalogue choices for bowls that are hard to reach.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC400C10MC2G AirTAC F.R.L. Combination, G3/8, Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C10MC2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.