The AirTAC GC400C10MC2GK AirTAC F.R.L. Combination, G3/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC400C10MC2GK is a three-piece AirTAC GC F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one unit. This 400-size configuration is ported G3/8 (G thread), carries a 40 um filter element with a manual drain, and is fitted with an external round gauge reading in psi. A reverse/check valve is fitted and the mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GC range is available in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, and options across the range include automatic or differential-pressure drains, a 5 um filter element (code W), embedded square or external round gauges with MPa, psi or bar scales, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application on request.
| Model | GC400C10MC2GK AirTAC F.R.L. Combination, G3/8 |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · See datasheet · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-C1 |
| Build order | Filter → regulator → lubricator |
Feeding clean, regulated and lubricated air to the cylinder circuit of a stamping press, where the 3/8 in line serves the main valve manifold and the psi gauge lets setters verify the working pressure.
Supplying the diverters and pick-and-place cylinders on a packaging line, with the filter removing water and particulate ahead of the valves and the lubricator misting the actuator air.
A bracket-mounted supply point for an assembly cell, where the regulator holds a stable set pressure for hand tools and fixtures and the manual drain is emptied during shift changeover.
Size and port step up together: 200 through 600 cover 1/8 to 1 inch ports, and the 400 size with its 3/8 inch port suits mid-range supply lines - match the size to the flow your circuit needs. Drain choice matters: this unit uses a manual drain, and the manual-drain version adjusts 0.05-0.9 MPa (7-130 psi); automatic and differential-pressure drain versions in the range adjust 0.15-0.9 MPa (20-130 psi). Filter grade is 40 um standard, with 5 um (code W) where finer filtration is needed. The round gauge on this model reads psi; embedded square gauges and MPa or bar scales are alternatives. Thread is G here; PT is the standard and G and NPT are catalogue options to order. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.
Flow for the GC400 is published as curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the datasheet flow figures for the 400 size at your working pressure on request.
This model uses a manual drain, so condensate is emptied by hand at intervals. Automatic and differential-pressure drain versions are available in the GC range; note that with those drain types the regulator adjustment range is 0.15-0.9 MPa (20-130 psi), while this manual-drain version adjusts 0.05-0.9 MPa (7-130 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.