The AirTAC GC400C10MC2W AirTAC F.R.L. Combination, PT3/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC400C10MC2W is a three-piece F.R.L. combination that filters, regulates and lubricates compressed air in one assembly: a separate filter, regulator and lubricator joined as a single air-preparation unit. This 400-size configuration is built with a PT3/8 (3/8 inch) port, a manual drain on the filter bowl, a fine 5 um filter element (the W grade, versus the standard 40 um), a round external pressure gauge reading in psi, and a mounting bracket included. The maximum inlet pressure is 1.0 MPa (145 psi), the regulator adjustment range for this manual-drain version is 0.05-0.9 MPa (7-130 psi), and the operating temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GC combination is available in sizes 200, 300, 400 and 600 with a choice of ports, drain types, filter grades, gauge styles and scales, and G or NPT thread options to order. Flow is published as curves rather than a single rated figure, so we confirm flow and other datasheet figures on request before you order.
| Model | GC400C10MC2W AirTAC F.R.L. Combination, PT3/8 |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · See datasheet · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-C1 |
| Build order | Filter → regulator → lubricator |
Feeding clean, regulated and lubricated air to the clamping cylinders and tool-change actuators on a CNC machining centre, where the 5 um element helps protect precision components and the round psi gauge gives the operator a clear setting reference.
Supplying treated air to the cylinders and air-driven grippers on a carton-forming and sealing line, with the regulator holding a steady working pressure and the lubricator carrying oil mist to keep actuators running smoothly through long shifts.
Preparing air for the pop-up diverters, stoppers and gate cylinders along a warehouse conveyor system, where the combination unit filters water and particulate, sets line pressure and lubricates the cylinders from a single PT3/8 connection.
Choose the size and port step against the air demand of the circuit: this unit is size 400 with a PT3/8 port; larger sizes carry larger ports and higher flow capacity. Because flow is published as curves and not as a single rating, ask us to confirm sizing against your application before ordering. For the drain, this version is manual (code M), meaning the bowl is drained by hand; automatic and differential-pressure drain options exist in the family if you prefer not to drain manually. The filter grade here is the fine 5 um element (code W) instead of the standard 40 um - pick 5 um where downstream equipment needs cleaner air. The gauge fitted is the external round type reading in psi; embedded square gauges and MPa or bar scales are the other catalogue choices. Thread is PT as standard, with G (BSPP) and NPT available as order options, and a mounting bracket is included.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.
AirTAC publishes flow for this series as performance curves rather than a single rated figure, so there is no one rated flow number we can quote. Send us your application details and we will confirm the flow and sizing from the datasheet on request before you order.
The M in GC400C10MC2W specifies a manual drain on the filter bowl, so collected water is emptied by hand as part of routine checks. The GC family also offers automatic and differential-pressure drain options if you want the bowl to discharge condensate without manual attention.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.