The AirTAC GC400C10MF2W AirTAC F.R.L. Combination, PT3/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC400C10MF2W is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one set. This size 400 configuration is built for 3/8 in PT ports and arrives with a manual drain on the filter bowl, a 5 um filter element (the finer of the two catalogue grades), a standard regulator adjustable from 0.05 to 0.9 MPa (7-130 psi), an embedded square gauge reading in psi, a metal bowl, and a mounting bracket included.
It is a genuine AirTAC part for compressed-air service at up to 1.0 MPa (145 psi) inlet pressure and -5 to 70 C (non-freezing). The GC line spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, plus choices of drain type, filter grade, gauge scale and G or NPT thread. Rated flow is published as curves rather than a single figure, so ask us to confirm the datasheet numbers for your application.
| Model | GC400C10MF2W AirTAC F.R.L. Combination, PT3/8 |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · See datasheet · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-C1 |
| Build order | Filter → regulator → lubricator |
Feeds spray guns and air-assisted applicators on a body-shop paint line, where the 5 um element, stable regulated pressure and controlled oil mist help keep finish quality consistent.
Supplies filtered, regulated and lubricated air to clamps, tool-changers and pneumatic actuators on a machining centre, with the psi gauge giving operators a visible setpoint at the drop.
Runs the cylinders and sealing jaws on a carton packaging conveyor, where the lubricator maintains a steady oil mist and the manual drain lets maintenance purge collected water at shift checks.
Step through the decodable choices in order. Size 400 with a 3/8 in PT port sits mid-range in the GC line; move up or down a size when the air demand of your cylinders and valves points to a different port. Drain: this unit is manual, so someone opens the drain periodically; automatic and differential-pressure drains are available on other codes if you cannot schedule that. Filter grade: 5 um here (code W) versus the 40 um standard - choose the finer element where downstream equipment is sensitive to fine particulate. The square gauge reads psi; MPa and bar scales are alternatives. Thread is PT as standard, with G (BSPP) and NPT as order options, and the bracket is included. Because rated flow is published only as curves, not a single number, send us your application and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the datasheet flow curves for the GC400 at 3/8 in before you order.
This code carries a manual drain: someone opens the drain periodically to purge collected water from the bowl. If you cannot schedule that, automatic and differential-pressure drain versions exist in the same family - ask us for the matching code. The 5 um element (code W) is likewise a choice against the 40 um standard.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.