verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC400C10MF2W AirTAC F.R.L. Combination, PT3/8

The AirTAC GC400C10MF2W AirTAC F.R.L. Combination, PT3/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$138.39 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC400C10MF2W AirTAC F.R.L. Combination, PT3/8

The GC400C10MF2W is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one set. This size 400 configuration is built for 3/8 in PT ports and arrives with a manual drain on the filter bowl, a 5 um filter element (the finer of the two catalogue grades), a standard regulator adjustable from 0.05 to 0.9 MPa (7-130 psi), an embedded square gauge reading in psi, a metal bowl, and a mounting bracket included.

It is a genuine AirTAC part for compressed-air service at up to 1.0 MPa (145 psi) inlet pressure and -5 to 70 C (non-freezing). The GC line spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, plus choices of drain type, filter grade, gauge scale and G or NPT thread. Rated flow is published as curves rather than a single figure, so ask us to confirm the datasheet numbers for your application.

GC400C10MF2W AirTAC F.R.L. Combination, PT3/8 Technical Specifications

ModelGC400C10MF2W AirTAC F.R.L. Combination, PT3/8
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC400C10MF2W AirTAC F.R.L. Combination, PT3/8

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the GC400C10MF2W AirTAC F.R.L. Combination, PT3/8 Is Used

factory

Automotive paint line

Feeds spray guns and air-assisted applicators on a body-shop paint line, where the 5 um element, stable regulated pressure and controlled oil mist help keep finish quality consistent.

precision_manufacturing

CNC machining cell

Supplies filtered, regulated and lubricated air to clamps, tool-changers and pneumatic actuators on a machining centre, with the psi gauge giving operators a visible setpoint at the drop.

conveyor_belt

Carton packaging line

Runs the cylinders and sealing jaws on a carton packaging conveyor, where the lubricator maintains a steady oil mist and the manual drain lets maintenance purge collected water at shift checks.

Is the GC400C10MF2W AirTAC F.R.L. Combination, PT3/8 the Right Station?

Step through the decodable choices in order. Size 400 with a 3/8 in PT port sits mid-range in the GC line; move up or down a size when the air demand of your cylinders and valves points to a different port. Drain: this unit is manual, so someone opens the drain periodically; automatic and differential-pressure drains are available on other codes if you cannot schedule that. Filter grade: 5 um here (code W) versus the 40 um standard - choose the finer element where downstream equipment is sensitive to fine particulate. The square gauge reads psi; MPa and bar scales are alternatives. Thread is PT as standard, with G (BSPP) and NPT as order options, and the bracket is included. Because rated flow is published only as curves, not a single number, send us your application and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

GC400C10MF2W AirTAC F.R.L. Combination, PT3/8 FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the datasheet flow curves for the GC400 at 3/8 in before you order.

This code carries a manual drain: someone opens the drain periodically to purge collected water from the bowl. If you cannot schedule that, automatic and differential-pressure drain versions exist in the same family - ask us for the matching code. The 5 um element (code W) is likewise a choice against the 40 um standard.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC400C10MF2W AirTAC F.R.L. Combination, PT3/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C10MF2W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.