verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC400C10MLC2GK AirTAC F.R.L. Combination G3/8 Low-Pressure

The AirTAC GC400C10MLC2GK AirTAC F.R.L. Combination G3/8 Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$149.37 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC400C10MLC2GK AirTAC F.R.L. Combination G3/8 Low-Pressure

The GC400C10MLC2GK is an AirTAC GC-series three-unit F.R.L. combination: a separate filter, regulator and lubricator assembled as one air-preparation set. This size 400 unit is configured for a G3/8 (BSPP) port, carries the standard 40 um filter element with a manual drain on the bowl, and uses the low-pressure regulator type. The code specifies the external round gauge with a psi scale, a reverse (check) valve, and an included mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GC series is published in sizes 200, 300, 400 and 600 with a choice of PT, G or NPT threads, manual, automatic or differential-pressure drains, 40 um or 5 um (W) filtration, gauge style and scale, and the low-pressure regulator option. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.

GC400C10MLC2GK AirTAC F.R.L. Combination G3/8 Low-Pressure Technical Specifications

ModelGC400C10MLC2GK AirTAC F.R.L. Combination G3/8 Low-Pressure
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC400C10MLC2GK AirTAC F.R.L. Combination G3/8 Low-Pressure

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the GC400C10MLC2GK AirTAC F.R.L. Combination G3/8 Low-Pressure Is Used

precision_manufacturing

Robotic welding cell

Feeds filtered, regulated and lubricated air to weld-clamp cylinders and robot gripper circuits, with the check valve holding the set circuit state between cycles.

conveyor_belt

Packaging line actuators

Prepares the air supply for conveyor stopper cylinders and carton-closing actuators, where the 40 um element protects valves from water and particulate carryover.

factory

Assembly plant tool ring

Supplies the overhead drops feeding air tools at assembly benches, delivering the oil-mist lubrication the tools need alongside clean, regulated pressure.

Is the GC400C10MLC2GK AirTAC F.R.L. Combination G3/8 Low-Pressure the Right Station?

Size and port step up together across the GC range (200 through 600), so pick the size whose published flow curve covers your demand at your working pressure; this unit is size 400 with a G3/8 port. The drain here is manual, which suits installations where the bowl can be bled on a schedule; automatic or differential-pressure drains are available if the unit will run unattended. Filtration is the standard 40 um element - choose the 5 um (W) option where finer protection is needed. The gauge in this code is the external round type with a psi scale; the embedded square gauge and MPa or bar scales are the alternatives. Thread is G (BSPP); PT is the standard and NPT is an order option. Because flow is published as curves, not a single rating, send us your air demand and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

GC400C10MLC2GK AirTAC F.R.L. Combination G3/8 Low-Pressure FAQ

Flow for the GC400 series is published as curves, not as a single rated number, so we do not quote a figure on the page. Tell us your working pressure and air demand and we will confirm the sizing from the AirTAC datasheet on request.

The M in the code selects a manual drain: the filter bowl is emptied by operating the drain when needed, typically during routine checks. If the unit will run unattended, the same series can be ordered with an automatic or differential-pressure drain instead - tell us and we will confirm the matching code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC400C10MLC2GK AirTAC F.R.L. Combination G3/8 Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C10MLC2GK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.