verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC400C10MLC2K AirTAC F.R.L. Combination, PT3/8

The AirTAC GC400C10MLC2K AirTAC F.R.L. Combination, PT3/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$149.87 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC400C10MLC2K AirTAC F.R.L. Combination, PT3/8

The GC400C10MLC2K is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator supplied as one set. This size-400 configuration is ported PT3/8 (3/8 in) with PT thread as standard. The filter section carries a 40 um element and a manual-drain polycarbonate bowl, so condensate is drained by hand on a schedule. The regulator is the low-pressure type, and this unit is specified with an external round gauge scaled in psi; a reverse (check) valve is fitted, and the mounting bracket is included.

This is a genuine AirTAC part. The GC series spans sizes 200, 300, 400 and 600, with port sizes from 1/8 in to 1 in, automatic or differential-pressure drain options, a 5 um filter element (code W), gauge scales in MPa, psi or bar, and G (BSPP) or NPT thread options to order. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.

GC400C10MLC2K AirTAC F.R.L. Combination, PT3/8 Technical Specifications

ModelGC400C10MLC2K AirTAC F.R.L. Combination, PT3/8
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC400C10MLC2K AirTAC F.R.L. Combination, PT3/8

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the GC400C10MLC2K AirTAC F.R.L. Combination, PT3/8 Is Used

factory

Plant air drops for an assembly hall

Feeding a distribution manifold that serves hand tools and air cylinders across a production hall, where one set has to remove water and particles, hold a set pressure and carry oil mist downstream to the points of use.

precision_manufacturing

CNC machining cell air supply

Supplying the air-actuated clamps and blow-off points on a machining centre, keeping the regulated circuit separate from the lubricated circuit while drawing from a single compressed-air drop.

conveyor_belt

Packaging line cylinder supply

Powering the pusher and clamp cylinders on a carton packaging conveyor, where the lubricator keeps the actuator seals moving smoothly through long shifts and the manual-drain bowl is emptied at scheduled checks.

Is the GC400C10MLC2K AirTAC F.R.L. Combination, PT3/8 the Right Station?

Size 400 with PT3/8 ports sits in the middle of the GC range; step to size 200, 300 or 600 when the application calls for a smaller or larger port and flow path. Drain type is a real decision: this unit uses a manual drain, while automatic and differential-pressure drains are available in the series if you cannot rely on scheduled draining. The 40 um element is the standard grade; specify code W for 5 um where finer particulate removal matters. The round gauge here reads in psi; MPa and bar scales are alternatives. Thread is PT as standard - G (BSPP) and NPT are order options, and the mounting bracket is included. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

GC400C10MLC2K AirTAC F.R.L. Combination, PT3/8 FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so there is no one number we can quote honestly. Send us your application details and we will confirm the flow figures from the datasheet for this size-400, PT3/8 combination before you order.

The L code marks the low-pressure regulator variant of the GC combination. A separate adjustment-range figure for this variant is not published in the material we hold, so we confirm the exact setting range from the datasheet on request. The unit otherwise keeps the standard three-unit layout - filter, regulator and lubricator - with the round psi gauge and reverse (check) valve fitted.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC400C10MLC2K AirTAC F.R.L. Combination, PT3/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C10MLC2K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.