verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC400C15AC2 AirTAC F.R.L. Combination, PT1/2

The AirTAC GC400C15AC2 AirTAC F.R.L. Combination, PT1/2 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$148.49 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC400C15AC2 AirTAC F.R.L. Combination, PT1/2

The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one conditioning set. This GC400C15AC2 is built for a PT1/2 (1/2 in) PT-threaded port and carries the 40 um standard filter element with an automatic drain, so collected water is expelled from the polycarbonate filter bowl without manual attention. The standard regulator adjusts outlet pressure across 0.15-0.9 MPa (20-130 psi) and a round gauge reading in psi is fitted; a mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GC range spans sizes 200, 300, 400 and 600, with manual or differential-pressure drains, a 5 um filter element (code W), gauge scales in MPa, psi or bar, and G or NPT threads as order options. Flow for this series is published as curves rather than a single figure, so ask us to confirm the datasheet and sizing for your application before ordering.

GC400C15AC2 AirTAC F.R.L. Combination, PT1/2 Technical Specifications

ModelGC400C15AC2 AirTAC F.R.L. Combination, PT1/2
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC400C15AC2 AirTAC F.R.L. Combination, PT1/2

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the GC400C15AC2 AirTAC F.R.L. Combination, PT1/2 Is Used

factory

Automotive weld-cell clamp cylinders

Conditioning the compressed air feeding clamp and weld-gun actuation cylinders on an automotive body line: water and particles removed, pressure held steady for consistent clamping force, and oil mist carried to the cylinder seals.

conveyor_belt

Bottling-line conveyor gating

Supplying treated air to the stopper and gate cylinders that index bottles along a filling line, where steady regulated pressure keeps indexing repeatable and lubrication helps the actuators run cleanly.

engineering

Maintenance workshop air drops

A conditioned drop at a plant maintenance bay feeding impact wrenches, air ratchets and blow guns: filtered and regulated supply with oil mist for the tools, at a 1/2 in PT connection.

Is the GC400C15AC2 AirTAC F.R.L. Combination, PT1/2 the Right Station?

Choose the size by port and flow: this size 400 unit takes a 1/2 in PT port, and stepping up or down a size changes both. Drain type is a real choice: automatic (this model) empties the filter bowl on its own, manual needs a periodic press, and differential-pressure drains only as the element loads up. Filter grade is 40 um standard or 5 um with code W if finer filtration is needed. Gauge scale (MPa, psi or bar) and thread (PT standard, G or NPT to order) are set at ordering. Flow for the GC series is published as curves, not a single rating, so ask us to confirm sizing against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

GC400C15AC2 AirTAC F.R.L. Combination, PT1/2 FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so there is no one number we can quote honestly. Send us your inlet pressure, downstream demand and allowable pressure drop, and we will confirm the datasheet curve and sizing for your application on request.

This model has an automatic drain, so condensate collected in the filter bowl is expelled without anyone attending it, which suits lines that run unattended. Manual and differential-pressure drains are order options across the GC range if you prefer a different arrangement.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC400C15AC2 AirTAC F.R.L. Combination, PT1/2

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C15AC2 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.