verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC400C15AC2W AirTAC F.R.L. Combination Unit, PT1/2, 5 um

The AirTAC GC400C15AC2W AirTAC F.R.L. Combination Unit, PT1/2, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$148.51 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC400C15AC2W AirTAC F.R.L. Combination Unit, PT1/2, 5 um

The GC400C15AC2W is an AirTAC GC three-unit F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator assembled as one 3-piece set, so the downstream air is cleaned of water and particulate, held at a set working pressure, and carries a fine oil mist for pneumatic tools and cylinders. This configuration is the size 400 unit with a 1/2 in PT port, the fine 5 um filter element (code W), an automatic drain on the filter bowl so collected condensate is ejected without manual attention, a round pressure gauge reading in psi, and a mounting bracket included. The maximum inlet pressure is 1.0 MPa (145 psi), the regulator adjustment range is 0.15-0.9 MPa (20-130 psi), and the working temperature range is -5 to 70 C (non-freezing). The filter bowl on this size is polycarbonate.

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with matching port sizes, and with options including manual or differential-pressure drain instead of automatic, the standard 40 um element instead of 5 um, square embedded or round external gauges with MPa, psi or bar scales, and G (BSPP) or NPT threads in place of PT. Flow is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.

GC400C15AC2W AirTAC F.R.L. Combination Unit, PT1/2, 5 um Technical Specifications

ModelGC400C15AC2W AirTAC F.R.L. Combination Unit, PT1/2, 5 um
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC400C15AC2W AirTAC F.R.L. Combination Unit, PT1/2, 5 um

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the GC400C15AC2W AirTAC F.R.L. Combination Unit, PT1/2, 5 um Is Used

factory

Automotive paint-shop air drops

Feeding spray guns and air-assisted applicators on a paint line, where the 5 um element, a stable regulated pressure and a controlled oil mist are all wanted at the drop, and the automatic drain copes with condensate from a long supply run.

conveyor_belt

Packaging line cylinder supply

Supplying the pneumatic cylinders on a carton-forming and case-sealing conveyor, where one point of filtration, regulation and lubrication at the line keeps sealing and diverting cylinders running consistently through the shift.

precision_manufacturing

CNC machine clamping circuits

Feeding the air-actuated clamps and tool-change actuators on a machining centre, where the regulator holds the clamping pressure set on the psi gauge and the lubricator mists the actuator internals continuously.

Is the GC400C15AC2W AirTAC F.R.L. Combination Unit, PT1/2, 5 um the Right Station?

Start with the port and size step: the GC400 with its 1/2 in PT port sits in the middle of the GC range (200/300/400/600), and the right step depends on the air consumption of the machines downstream - ask us to check the published flow curves against your demand before ordering, since there is no single rated flow number to quote. Choose the drain: automatic (this unit) ejects condensate on its own, manual needs someone to open the drain, and differential-pressure draining is the default on other variants. Choose the element: 40 um is the standard grade, this unit carries the finer 5 um (W) element for cleaner air. The gauge here is the external round type reading in psi; embedded square gauges and MPa or bar scales are the other catalogue choices. Thread is PT as standard, with G (BSPP) and NPT available to order, and a mounting bracket is included with this unit.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

GC400C15AC2W AirTAC F.R.L. Combination Unit, PT1/2, 5 um FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote one number. Tell us your working pressure and the air consumption of the equipment downstream, and we will confirm the sizing from the datasheet on request before you order.

The A in the code sets the automatic drain, so the filter bowl ejects collected condensate by itself instead of waiting for a manual drain; the W sets the finer 5 um element instead of the standard 40 um. Both are catalogue choices - manual or differential-pressure drains and the 40 um element are available on other GC400 variants if you prefer them.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC400C15AC2W AirTAC F.R.L. Combination Unit, PT1/2, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C15AC2W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.