The AirTAC GC400C15AC2WK AirTAC F.R.L. Combination, PT1/2 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$159.86 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC400C15AC2WK AirTAC F.R.L. Combination, PT1/2

The GC400C15AC2WK is a genuine AirTAC GC-series three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one unit. This size 400 configuration is built for a 1/2 in PT port and carries the fine 5 um filter element (code W) instead of the standard 40 um grade, so both water and fine particulate are stripped before air reaches the regulator and lubricator. The filter bowl drains automatically, the regulator is the standard type with a fitted round gauge scaled in psi, and a reverse/check valve is fitted to hold the downstream setting. At size 400 the bowls are polycarbonate. The maximum inlet pressure is 1.0 MPa (145 psi), the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi), and the unit operates from -5 to 70 C in non-freezing conditions. A mounting bracket is included.

This is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and options that include manual or differential-pressure drains, a 40 um standard element, gauge scale choices in MPa, psi or bar, and G (BSPP) or NPT threads in place of the PT standard. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing figures for your application on request.

GC400C15AC2WK AirTAC F.R.L. Combination, PT1/2 Technical Specifications

ModelGC400C15AC2WK AirTAC F.R.L. Combination, PT1/2
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC400C15AC2WK AirTAC F.R.L. Combination, PT1/2

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the GC400C15AC2WK AirTAC F.R.L. Combination, PT1/2 Is Used

factory

Automotive assembly line air drops

At a 1/2 in plant air drop, this F.R.L. set conditions the supply feeding impact wrenches, nut runners and pneumatic clamps: water and fine particles removed at 5 um, pressure held steady by the regulator, and a controlled oil mist carrying the tools.

conveyor_belt

Packaging and palletising line actuators

Packaging machines and palletiser cylinders run for thousands of cycles a shift. This unit gives that line clean, regulated and lubricated air at the half-inch feed, with the check valve helping hold the set pressure and the automatic drain keeping the bowl clear unattended.

settings_input_component

Machine tool pneumatic control cabinets

CNC and special-purpose machines with air-assisted tool changes, clamping and chip ejection need one conditioned supply point. This three-unit set mounted on its bracket at the machine inlet delivers filtered, regulated, lubricated air to those circuits from a 1/2 in PT connection.

Is the GC400C15AC2WK AirTAC F.R.L. Combination, PT1/2 the Right Station?

Start with the port and size step: size 400 with a 1/2 in PT port sits in the upper-middle of the GC range (200/300/400/600), so step up to 600 or step down to 300 according to the flow your line needs - we will confirm the flow curve against your demand before you order. This unit already carries the fine 5 um element (the standard is 40 um; choose W only where downstream valves and cylinders genuinely need finer air). The automatic drain here empties the filter bowl without daily attention; manual and differential-pressure drain versions exist if you prefer a different regime. The fitted round gauge reads in psi; embedded square gauges and MPa or bar scales are the alternatives. Thread is the PT standard - G (BSPP) and NPT are catalogue options to order as specification, not a delivery matter. A mounting bracket is included with this configuration.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

GC400C15AC2WK AirTAC F.R.L. Combination, PT1/2 FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a figure here. Tell us your line demand and working pressure and we will confirm the flow curve and correct size from the datasheet on request before you order.

The W in the code specifies the optional 5 um filter element instead of the 40 um standard, for finer water and particulate removal ahead of the regulator and lubricator. The A specifies an automatic drain, which expels collected condensate from the filter bowl without manual attention - manual and differential-pressure drain versions are available if your maintenance regime prefers them.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC400C15AC2WK AirTAC F.R.L. Combination, PT1/2

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C15AC2WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.