AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC400C15ALC2GK AirTAC F.R.L. Combination, G1/2

The AirTAC GC400C15ALC2GK AirTAC F.R.L. Combination, G1/2 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$159.50 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC400C15ALC2GK AirTAC F.R.L. Combination, G1/2

The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator, assembled as one air-treatment set for compressed-air lines. This configuration is the GC400 size with a G1/2 (BSPP) port, an automatic drain on the filter bowl so collected condensate is expelled without manual attention, a 40 um standard filter element, a low-pressure type regulator, a round pressure gauge reading in psi, a fitted reverse/check valve, and a mounting bracket included. The maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600, with port options, drain types (differential-pressure, automatic or manual), a 5 um optional filter element (code W), gauge scale choices and thread options (PT standard; G and NPT orderable as specifications). Flow is published as curves rather than a single rated figure, so we confirm the datasheet and flow figures for your application on request.

GC400C15ALC2GK AirTAC F.R.L. Combination, G1/2 Technical Specifications

ModelGC400C15ALC2GK AirTAC F.R.L. Combination, G1/2
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC400C15ALC2GK AirTAC F.R.L. Combination, G1/2

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the GC400C15ALC2GK AirTAC F.R.L. Combination, G1/2 Is Used

precision_manufacturing

CNC machining center air supply

Feeding filtered, regulated and lubricated air to the tool-clamp and pallet-change circuits of a CNC machining center, with the automatic drain keeping condensate out of the valves during long unattended runs.

factory

Automotive paint booth line prep

Conditioning shop air ahead of spray guns and air-assisted transfer pumps in an automotive paint booth, where the 40 um element removes water and particulate and the lubricator mists oil for downstream air motors.

conveyor_belt

Packaging line actuator supply

Supplying treated air to the cylinders and grippers on a carton-forming and case-packing conveyor line, with the low-pressure regulator set for the actuator circuit and the psi gauge giving operators a local reading.

Is the GC400C15ALC2GK AirTAC F.R.L. Combination, G1/2 the Right Station?

Start with the size and port: the GC series steps through sizes 200, 300, 400 and 600, each with its own port range, so pick the size whose flow curve covers your line demand - we can check the curve against your consumption before you order. Then set the drain: differential-pressure (default), automatic (this unit) or manual. Choose the filter grade - 40 um standard or 5 um (code W) for finer particulate. Select the gauge type and scale (MPa, psi or bar; this unit carries a round psi gauge). Pick the thread - PT is the standard, with G (BSPP) and NPT orderable as specifications - and whether a bracket is fitted (included here).

One honest note on sizing: AirTAC publishes flow as curves, not as a single rated number, so ask us to confirm the flow figures for this GC400 against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

GC400C15ALC2GK AirTAC F.R.L. Combination, G1/2 FAQ

AirTAC publishes flow for the GC400 as curves rather than a single rated figure, so we do not quote a rated flow number. Send us your line pressure and air consumption and we will confirm the flow figures from the datasheet for your application on request.

The L code marks the low-pressure type regulator, intended for circuits set below the standard range; the exact adjustment range is not published in the material we hold, so we confirm it on request. The A code means the filter bowl has an automatic drain, which expels collected condensate by itself instead of waiting for a manual or differential-pressure drain cycle.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC400C15ALC2GK AirTAC F.R.L. Combination, G1/2

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C15ALC2GK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.