verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC400C15ALF2G AirTAC F.R.L. Combination, G1/2, Low-Pressure

The AirTAC GC400C15ALF2G AirTAC F.R.L. Combination, G1/2, Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$148.16 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC400C15ALF2G AirTAC F.R.L. Combination, G1/2, Low-Pressure

The GC400C15ALF2G is an AirTAC GC three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one set. This configuration is size 400 with G1/2 (G/BSPP thread) ports, an automatic drain on the filter bowl, the standard 40 um filter element, a low-pressure regulator type, and an embedded square gauge reading in psi. It conditions compressed air in one pass - removing water and particulate, holding a set downstream pressure, and adding oil mist for air tools and cylinders. Maximum working (inlet) pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GC line comes in sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, and options that include manual or differential-pressure drains, a 5 um (W) filter element, MPa or bar gauge scales, an external round gauge, a reverse/check valve, and PT or NPT threads in place of G. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.

GC400C15ALF2G AirTAC F.R.L. Combination, G1/2, Low-Pressure Technical Specifications

ModelGC400C15ALF2G AirTAC F.R.L. Combination, G1/2, Low-Pressure
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC400C15ALF2G AirTAC F.R.L. Combination, G1/2, Low-Pressure

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the GC400C15ALF2G AirTAC F.R.L. Combination, G1/2, Low-Pressure Is Used

factory

Automotive paint-shop air supply

Filtered, regulated and lubricated air to spray guns and air motors on a paint line, where the low-pressure regulator holds a gentle setpoint and the 40 um element keeps water and grit out of the finish.

precision_manufacturing

CNC machining-centre pneumatics

Supplying clamps, air chucks and tool-change cylinders on a machining centre, with the lubricator feeding oil mist downstream and the psi gauge giving operators a visible setpoint at the machine.

conveyor_belt

Packaging and conveyor actuation

Running diverters, pushers and conveyor-mounted cylinders on a packaging line, where the automatic drain clears condensate and the set keeps every actuator fed with clean, regulated, lubricated air.

Is the GC400C15ALF2G AirTAC F.R.L. Combination, G1/2, Low-Pressure the Right Station?

The real choices on this series are decodable from the code. Step the size (200/300/400/600) and port to match the flow your line needs - this unit is size 400 with 1/2 in ports. On the filter you pick the drain: automatic (as here), manual, or differential-pressure, and the element grade: 40 um standard or 5 um (W) for finer filtration. On the regulator you choose standard or low-pressure (L) type, and the gauge: embedded square as standard with MPa, psi or bar scales, or an optional external round gauge. Threads come as PT (the standard), G or NPT; a mounting bracket is included on this set. One honest note: flow is published as curves, not a single rating, so send us your application and we will confirm sizing from the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

GC400C15ALF2G AirTAC F.R.L. Combination, G1/2, Low-Pressure FAQ

AirTAC publishes flow for this series as performance curves rather than a single rated figure, so we do not quote a number here. Tell us your application and required flow, and we will confirm the sizing from the datasheet on request before you order.

The trailing G means G (BSPP) parallel thread on the 1/2 in ports. PT is the standard thread for this series, and G and NPT are catalogue options selected by code - this unit is simply built with the G option. Thread choice is a specification, not a delivery promise.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC400C15ALF2G AirTAC F.R.L. Combination, G1/2, Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C15ALF2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.