verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC400C15F2GK AirTAC F.R.L. Combination Unit, G1/2

The AirTAC GC400C15F2GK AirTAC F.R.L. Combination Unit, G1/2 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$149.00 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC400C15F2GK AirTAC F.R.L. Combination Unit, G1/2

The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator, assembled as one set so a compressed-air supply can be cleaned, regulated and lubricated at a single take-off point. This configuration is the size 400 unit with a G1/2 (BSPP) port, the standard 40 um filter element and a differential-pressure drain that bleeds collected water automatically whenever the pressure differential across the element is high enough. The regulator is the standard type with a fitted square gauge scaled in psi, and a reverse/check valve is fitted so downstream pressure is held if the upstream supply is lost. The filter and lubricator bowls on this size are polycarbonate.

This is a genuine AirTAC part from the GC range, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, and options including automatic or manual drains, a 5 um filter element (code W), gauge scales in MPa, psi or bar, and PT, G or NPT threads. We do not publish a single rated-flow figure - flow appears in the catalogue as curves - so ask us to confirm sizing and datasheet figures for your application before ordering.

GC400C15F2GK AirTAC F.R.L. Combination Unit, G1/2 Technical Specifications

ModelGC400C15F2GK AirTAC F.R.L. Combination Unit, G1/2
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC400C15F2GK AirTAC F.R.L. Combination Unit, G1/2

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the GC400C15F2GK AirTAC F.R.L. Combination Unit, G1/2 Is Used

precision_manufacturing

CNC machining cell air supply

Feeding a machine tool's pneumatic clamps, tool-changer cylinders and air-blast nozzles from one take-off: the filter strips water and swarf-laden particulate, the regulator holds a steady setting at the fixture, and the lubricator mists oil to the actuated components.

air

Automotive paint-shop supply drop

A wall-mounted supply point at a spray booth or prep station, where the filter removes water that would fish-eye the finish, the regulator sets a consistent gun pressure, and the lubricator conditions air tools used at the same station.

conveyor_belt

Packaging and carton-sealing line

Supplying the cylinders, grippers and vacuum generators along a packaging conveyor: clean, regulated air keeps sealing and case-packing motions repeatable through the shift, and the lubricator services the air cylinders running continuously on the line.

Is the GC400C15F2GK AirTAC F.R.L. Combination Unit, G1/2 the Right Station?

Start with the port and size: this unit is size 400 with a 1/2 inch port; step up or down through the 200/300/400/600 range to match the pipe size and duty of your line, and let us confirm the flow against your demand before you order. Drain choice matters: the differential-pressure drain fitted here needs no daily attention, while automatic (code A) drains continuously and manual (code M) drains only when operated - the manual-drain version also widens the regulator adjustment range down to 0.05 MPa. The standard element is 40 um; specify code W for 5 um where finer particulate removal matters. The square gauge here reads psi; MPa and bar scales and an external round gauge are alternatives. Thread is G (BSPP) on this model, with PT as the catalogue standard and NPT available to order. A mounting bracket is included.

Because flow is published as curves rather than a single rating, send us your application details and we will confirm the right size before you commit.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

GC400C15F2GK AirTAC F.R.L. Combination Unit, G1/2 FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a figure here. Tell us your line pressure and the air demand of your equipment, and we will confirm the sizing against the datasheet curves on request before you order.

The K in the model code means a reverse/check valve is fitted, so air already downstream of the set is held if the upstream supply drops - useful where a cylinder or clamp must not release on a supply loss. The differential-pressure drain on the filter bowl ejects collected condensate automatically when the pressure differential across the element rises, with no manual draining needed in normal service.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC400C15F2GK AirTAC F.R.L. Combination Unit, G1/2

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C15F2GK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.