AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC400C15F2K AirTAC F.R.L. Combination, PT1/2

The AirTAC GC400C15F2K AirTAC F.R.L. Combination, PT1/2 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$149.50 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC400C15F2K AirTAC F.R.L. Combination, PT1/2

The GC400C15F2K is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one supply package. This 400-size unit is ported PT1/2 and carries the standard 40 um filter element with a differential-pressure drain on the filter bowl, so collected water is expelled automatically as the pressure differential across the drain rises - no daily manual draining on a busy line. The regulator is the standard type with a 0.15-0.9 MPa (20-130 psi) adjustment range, read on the fitted embedded square gauge scaled in psi, and a reverse/check valve is fitted so downstream pressure is held if the upstream supply is lost. For size 400 the filter bowl is PC (polycarbonate); the bowl is aluminium alloy only at size 600.

This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600, with port options from 1/8 to 1 inch, G or NPT thread variants, automatic, manual or differential-pressure drains, a 5 um (code W) filter element, gauge scales in MPa, psi or bar, and round-gauge or no-gauge options. Rated flow for this combination is published as curves rather than a single figure - ask us and we will confirm the datasheet figures against your application.

GC400C15F2K AirTAC F.R.L. Combination, PT1/2 Technical Specifications

ModelGC400C15F2K AirTAC F.R.L. Combination, PT1/2
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC400C15F2K AirTAC F.R.L. Combination, PT1/2

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the GC400C15F2K AirTAC F.R.L. Combination, PT1/2 Is Used

conveyor_belt

Bottling-line conveyor actuators

On a bottling or canning line, pusher and stopper cylinders along the conveyor run continuously off a 1/2 inch ring main. This unit filters water and scale from the supply, holds a set working pressure at the actuators, and meters oil mist so cylinder seals and valves last through long production shifts.

factory

Automotive assembly air-tool drops

At an automotive assembly plant, impact wrenches and nutrunners at a workstation take their air from a 1/2 inch drop. Clean, regulated, lubricated air keeps tools running at a consistent torque and protects the vane motors, while the check valve holds downstream pressure if the main is isolated.

engineering

Machine-shop pneumatic clamping

On a CNC machining cell with pneumatic workholding clamps, a stable supply pressure is critical to clamp force repeatability. This three-unit package on the cell's 1/2 inch supply removes condensate and chips-carrying particulate, regulates the clamp circuit pressure read in psi, and lubricates the clamp cylinders.

Is the GC400C15F2K AirTAC F.R.L. Combination, PT1/2 the Right Station?

Size and port are the first choice: step up from 200 through 600 as your port size and air demand grow - this unit is the 400 size with a 1/2 inch PT port. Drain type is a real decision on the filter: differential-pressure (this unit) drains automatically as the element loads, automatic (code A) drains on a level or timer principle, and manual (code M) needs someone to open the drain. Filter grade is 40 um standard or 5 um with code W if downstream equipment needs finer particulate removal. The gauge here is the embedded square type scaled in psi; MPa and bar scales and an external round gauge are order options. Thread is PT as standard, with G (BSPP) and NPT as catalogue options to order, and a reverse/check valve (code K) is fitted on this unit. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

GC400C15F2K AirTAC F.R.L. Combination, PT1/2 FAQ

AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote one number. Tell us your line pressure and the air demand of your equipment and we will confirm the datasheet flow curves for this 400-size, PT1/2 unit against your application before you order.

K is the reverse (check) valve option: a valve is fitted that holds downstream pressure if the upstream supply is lost or the unit is isolated. On circuits such as pneumatic clamping this keeps the set pressure at the actuators instead of letting it bleed back. Units without the K code have no check valve fitted.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC400C15F2K AirTAC F.R.L. Combination, PT1/2

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C15F2K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.