verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC400C15F2WGK AirTAC F.R.L. Combination, G1/2

The AirTAC GC400C15F2WGK AirTAC F.R.L. Combination, G1/2 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$149.01 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC400C15F2WGK AirTAC F.R.L. Combination, G1/2

The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator assembled as one supply unit that cleans, regulates and lubricates compressed air downstream. This GC400 configuration is built for 1/2 in ports with G (BSPP) thread, carries the fine 5 um filter element (code W) instead of the 40 um standard, and drains the filter bowl by differential pressure, so the bowl purges as the pressure across the element builds. The standard regulator covers an adjustment range of 0.15-0.9 MPa (20-130 psi), a psi-scale gauge is fitted so the set pressure can be read directly, and a reverse/check valve (code K) holds downstream pressure if the upstream supply drops. The mounting bracket is included.

This is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600, so the same three-unit layout is available from 1/8 in up to 1 in ports, with manual or automatic drain, 40 um or 5 um filtration, MPa, psi or bar gauge scales, and PT, G or NPT threads as order options. AirTAC publishes flow for this series as curves rather than a single rated figure, so ask us and we will confirm the sizing and datasheet figures for your application before you order.

GC400C15F2WGK AirTAC F.R.L. Combination, G1/2 Technical Specifications

ModelGC400C15F2WGK AirTAC F.R.L. Combination, G1/2
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC400C15F2WGK AirTAC F.R.L. Combination, G1/2

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the GC400C15F2WGK AirTAC F.R.L. Combination, G1/2 Is Used

precision_manufacturing

CNC machining centre air supply

Feeds clean, regulated and lubricated air to the tool-change clamps, pneumatic chucks and coolant-mist circuits of a machining centre, with the 5 um element protecting fine spool valves on a 1/2 in shop-air drop.

conveyor_belt

Packaging and case-sealing line

Supplies the diverters, sealers and vacuum generators along a packaging conveyor, where the check valve keeps actuators from drifting if the main supply dips mid-cycle and the lubricator mists the cylinder seals.

factory

Automotive assembly cell FRL point-of-use

Mounted at the drop of a plant-air header in an assembly cell, it conditions air for impact tools, clamping fixtures and air-fed workstations, with the psi gauge letting maintenance set and verify the cell pressure.

Is the GC400C15F2WGK AirTAC F.R.L. Combination, G1/2 the Right Station?

Start with the port and size step: this unit is size 400 with 1/2 in G-thread ports; if your line needs less or more air, the same combination exists in sizes 200, 300 and 600. You have already chosen the fine 5 um element (W); the 40 um standard element suits general plant air and loads the drain less, so step down to 5 um only where downstream valves, cylinders or instruments need the cleaner air. The differential-pressure drain is hands-off; a manual-drain (M) or automatic-drain (A) version can be ordered instead if your duty cycle or bowl orientation calls for it. Gauge scale is set here to psi; MPa or bar scales are available, and an embedded square gauge can replace the fitted round gauge. Thread is G (BSPP) on this code, with PT as the standard and NPT as an order option, and the bracket is included. Flow for the GC series is published as curves, not a single rating, so send us your air demand and we will confirm the correct size against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

GC400C15F2WGK AirTAC F.R.L. Combination, G1/2 FAQ

AirTAC publishes flow for the GC series as performance curves, not as a single rated figure, so we do not quote one number. Tell us your air demand and line pressure and we will confirm the sizing against the datasheet on request before you order.

The W in the code GC400C15F2WGK selects the optional 5 um filter element in place of the 40 um standard. Choose 5 um where downstream valves, instruments or air-fed equipment need finer particle removal; choose 40 um for general plant air. Both grades are available across the GC range, and the drain choice (differential-pressure, automatic or manual) is independent of the grade.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC400C15F2WGK AirTAC F.R.L. Combination, G1/2

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C15F2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.